In a resistivity survey, four electrodes are placed in the ground: two to inject current and two to measure voltage. How you arrange them is called the electrode array. The choice of array changes how deep you see, what features you detect and how noisy the data are. The three most widely used are Wenner, Schlumberger and dipole-dipole. This article compares them.
Basic terms
- A and B: the current electrodes.
- M and N: the potential electrodes.
- Geometric factor (K): converts measured resistance (voltage ÷ current) into apparent resistivity. It depends on the array and spacing.
- Apparent resistivity: the resistivity of a uniform ground that would give the same reading. See apparent and true resistivity.
Wenner array
All four electrodes are equally spaced in a line: A, M, N, B, with spacing “a” between each. The geometric factor is K = 2πa.
- Strengths: strong signal, good in noisy areas; good resolution of horizontal layers.
- Weaknesses: all four electrodes move for each reading, which is slow for soundings; less sensitive to vertical features; smaller coverage at depth in 2D surveys.
- Typical use: shallow engineering surveys, earthing studies, 2D ERT in noisy environments.
Schlumberger array
The potential electrodes M and N are close together in the centre; the current electrodes A and B are spread outward symmetrically. For soundings, only A and B are moved for most readings, with MN expanded occasionally. With AB/2 = L and MN/2 = l, the geometric factor is approximately K = π(L² − l²) ÷ 2l.
- Strengths: efficient for VES, as fewer electrodes move; good vertical resolution of layered ground; less affected by near-surface variations at the potential electrodes.
- Weaknesses: weaker signal at large spacings; shifts in curves when MN is changed need care.
- Typical use: vertical electrical sounding for borehole siting, the standard method in much of East Africa. Wenner-Schlumberger hybrid arrays are common in 2D ERT.
Dipole-dipole array
The current pair (A and B) and potential pair (M and N) are separated, each with spacing “a”, and the distance between the pairs is n × a. Increasing n increases depth.
- Strengths: very sensitive to lateral changes and vertical structures such as faults, dykes, fracture zones and mineralised veins; efficient for multi-channel 2D and 3D surveys.
- Weaknesses: signal drops quickly with n, so data are noisier at depth; needs good equipment and careful field practice.
- Typical use: 2D ERT and IP for fractured rock aquifers, mineral exploration, cavities and contamination.
Pole-dipole and pole-pole
In these arrays, one or two electrodes are placed far away (“at infinity”). Pole-dipole gives greater depth for a given line length and good coverage, and is widely used in IP surveys. Pole-pole gives the greatest depth but is very sensitive to noise and needs long remote cables.
Comparison
| Array | Signal strength | Vertical resolution (layers) | Lateral resolution (faults, dykes) | Depth for line length |
|---|---|---|---|---|
| Wenner | High | Good | Moderate to low | Moderate |
| Schlumberger / Wenner-Schlumberger | Moderate to high | Good | Moderate | Moderate to good |
| Dipole-dipole | Low | Moderate | High | Good |
| Pole-dipole | Moderate | Moderate | Good | Very good |
Choosing an array
Layered sedimentary or volcanic aquifers
Schlumberger VES, or Wenner-Schlumberger ERT, gives reliable layer depths and resistivities.
Fractured basement rock
Water is often in narrow, steep fractures. Use profiling or dipole-dipole ERT to locate them, then VES at the target if needed. See 2D ERT.
Engineering sites
Wenner or Wenner-Schlumberger for rock head and layering; dipole-dipole for cavities and faults.
Mineral exploration
Dipole-dipole or pole-dipole, usually with IP. See IP surveys.
Noisy urban sites
Wenner or Wenner-Schlumberger for stronger signals; increase stacking.
Many 2D surveys collect two arrays on the same line and invert them together, combining their strengths.
Depth of investigation
Depth depends on electrode spacing, array and ground resistivity. As a rough rule, maximum depth for many arrays is a fraction of the total line length, often around one-fifth to one-sixth, but sensitivity decreases with depth and conductive layers near the surface reduce penetration. Inversion software can calculate a depth of investigation index for each section.
How Quantum Geoconsultants can help
We choose arrays to suit the geology and question, and often combine VES and ERT for groundwater and engineering projects. See our geophysical surveys and ERT surveys in Kenya.
Frequently asked questions
Which array is best for groundwater borehole siting?
The Schlumberger array is the most common for vertical electrical sounding in groundwater work because it is efficient in the field and gives good vertical resolution of layered ground.
Which array is best for detecting faults and fractures?
Dipole-dipole is more sensitive to vertical structures such as faults, fracture zones and dykes, which makes it useful in 2D ERT for fractured rock aquifers and mineral targets, though its signal is weaker.
What is the geometric factor?
A number that depends on electrode spacing and arrangement. It converts the measured resistance into apparent resistivity, so readings from different spacings and arrays can be compared.
📡 Request a geophysical survey quote
The cost of a geophysical survey depends mainly on the area or length of survey lines, the methods and depth of investigation needed, and site access. Tell us about your project and we will propose a survey design and quotation.
We reply with a proposed survey design and quotation. Prices are not listed online because every site and target is different.
Plan your geophysical survey
Tell us your site, target and depth of interest. We will recommend the right methods and send a survey design and quotation.