Get a Quote
← All articles

Typical Resistivity Values of Rocks, Soils and Water

A reference table of typical electrical resistivity ranges for water, soils, sediments and rocks, the factors that control resistivity, and how to use these values when interpreting surveys.

By Quantum Geoconsultants geophysics teamUpdated 20 November 20262 min read
TopsoilLava flowFractured lava flowWater between lava flowsOlder lavas & tuffs Resistivity survey Methods chosen for your target

📡 Geophysical Surveys: a technical article by the Quantum Geoconsultants geophysics team.

Interpreting a resistivity survey means turning numbers in ohm-metres into geology: clay, sand, weathered rock, fresh granite, saline water. Reference tables of typical resistivity values are a useful starting point. But they must be used with care, because values for different materials overlap widely. This article gives typical ranges and explains what controls them.

What controls resistivity?

Most rock-forming minerals are very poor conductors. In the ground, electric current flows mainly through water in pores and fractures, and along the surfaces of clay minerals. So resistivity depends mostly on:

Archie’s law describes this relationship in clean, clay-free sediments.

Typical ranges

Values are approximate and drawn from widely used geophysical references. Local values may differ.

Water

Material Typical resistivity (ohm-m)
Rainwater About 30 to 1,000
Fresh groundwater About 10 to 100
Brackish water About 1 to 10
Seawater About 0.2

Soils and sediments

Material Typical resistivity (ohm-m)
Clay (saturated) About 1 to 100
Silt About 10 to 200
Sand and gravel, saturated with fresh water About 50 to 1,000
Sand and gravel, dry About 500 to 10,000+
Sand saturated with saline water About 1 to 10
Topsoil Highly variable, about 10 to 1,000+
Laterite and murram About 100 to 1,000+

Rocks

Material Typical resistivity (ohm-m)
Fresh granite and gneiss About 1,000 to 100,000+
Weathered granite and gneiss (saprolite) About 20 to 500
Fractured basement, water-bearing About 100 to 1,000
Basalt, fresh About 1,000 to 10,000+
Basalt, weathered or fractured About 20 to 500
Volcanic tuff and ash About 10 to 500
Limestone, massive About 100 to 10,000
Coral limestone, saturated About 10 to 1,000, lower with saline water
Sandstone About 10 to 1,000+
Shale and mudstone About 1 to 100
Gypsum and anhydrite About 100 to 10,000+
Graphitic schist Below 1 to 100
Massive sulphides Below 1

Overlap: the interpretation challenge

Look at the tables and you will see that a reading of 30 ohm-m could be:

Only geological knowledge, nearby borehole logs and sometimes additional methods such as IP or EM can separate them. This is why resistivity surveys for borehole siting are probabilities, not guarantees.

Typical patterns in East Africa

Setting Typical resistivity pattern
Basement areas (eastern Kenya, northern Somalia) Resistive topsoil or laterite, conductive weathered zone, resistive fresh rock; best water often at the base of weathering and in fractures
Rift Valley volcanics Alternating resistive lavas and conductive tuffs, old soils and weathered zones
Coastal sediments and coral Moderate resistivity freshwater lens over very low resistivity saline zone
Arid sedimentary basins Dry resistive surface, then conductive layers that may be clay or saline water

See interpreting resistivity profiles and resistivity in coastal areas.

Using the tables well

  1. Start with the geology map and nearby borehole logs.
  2. Calibrate: run a sounding next to an existing borehole where possible.
  3. Compare relative changes rather than absolute values.
  4. Measure the EC of local groundwater to estimate its resistivity.
  5. Use IP or EM where clay and saline water must be separated.

How Quantum Geoconsultants can help

We interpret resistivity data with local geology and borehole records, which matters more than any table. See our geophysical surveys in Kenya and hydrogeological surveys in Somalia.

Frequently asked questions

What is the resistivity of fresh groundwater?

Fresh groundwater commonly has resistivity in the range of about 10 to 100 ohm-metres. Brackish and saline water have much lower values, and seawater is around 0.2 ohm-metres.

Why do clay and salty water both have low resistivity?

Clay minerals conduct electricity through charged surfaces and pore water, and salty water contains many dissolved ions. Both reduce resistivity, which is why they can be hard to tell apart on resistivity data alone.

Can resistivity tables identify rock types?

Only approximately. Ranges for different rocks overlap widely, and water content, weathering, fractures and salinity change the values. Tables are a guide, used together with geology and borehole data.

📡 Request a geophysical survey quote

The cost of a geophysical survey depends mainly on the area or length of survey lines, the methods and depth of investigation needed, and site access. Tell us about your project and we will propose a survey design and quotation.

We reply with a proposed survey design and quotation. Prices are not listed online because every site and target is different.

Plan your geophysical survey

Tell us your site, target and depth of interest. We will recommend the right methods and send a survey design and quotation.

💬 WhatsApp