Anyone reading a resistivity survey report will see the terms apparent resistivity and true resistivity. Confusing the two leads to wrong interpretations. This article explains the difference simply.
True resistivity
True resistivity is a physical property of a material, measured in ohm-metres (Ωm). A uniform block of saturated sand, clay or granite has a particular true resistivity determined by its mineralogy, porosity, water content and water salinity.
Apparent resistivity
In the field we cannot measure a single layer directly. We inject current through two electrodes and measure voltage between two others. The calculated value is:
ρa = K × ΔV / I
where ΔV is voltage, I is current and K is the geometric factor for the electrode arrangement. If the ground were perfectly uniform, ρa would equal its true resistivity. In real, layered ground, ρa is a weighted average of the resistivities of all the material the current passes through. That is why it is called apparent.
The geometric factor
K depends only on electrode positions. For the Wenner array with spacing a, K = 2πa. For Schlumberger and other arrays there are standard formulas. Using the wrong K gives wrong apparent resistivities, so field records must note exact electrode positions.
How apparent resistivity changes with spacing
Small electrode spacings mostly sample shallow ground, so ρa approaches the resistivity of the top layer. As spacing increases, deeper layers contribute more. On a sounding curve:
- At small spacings, ρa approaches the top layer’s true resistivity.
- At large spacings, ρa approaches the deepest layer’s value, if spacing is large enough.
- Thin middle layers may never be shown at their true resistivity on the curve.
A simple example
Consider 5 m of dry sand (1,000 Ωm) over 20 m of saturated weathered rock (60 Ωm) over fresh granite (5,000 Ωm). The apparent resistivity starts near 1,000 Ωm, falls as current enters the weathered zone, but never reaches 60 Ωm, then rises again at large spacings as the granite takes effect. Only inversion can recover the true 60 Ωm and the layer thickness.
Recovering true resistivity: inversion
Inversion software builds a model of the subsurface, calculates its apparent resistivity response and adjusts it until it matches the field data. For VES, the model is a set of layers. For ERT, it is a grid of cells. The result is an estimate of true resistivity distribution, not a unique answer.
Non-uniqueness
- Equivalence: a thin layer of low resistivity and a thicker layer of slightly higher resistivity can give nearly identical responses.
- Suppression: a thin layer with resistivity between its neighbours may not be detectable.
Borehole information and geology are used to choose the most realistic model. See limitations of geophysical surveys.
Why it matters in practice
Reading an apparent resistivity value as the property of a single layer can lead to wrong conclusions, for example assuming a moderately low reading means a thick aquifer when it is the blended effect of clay and rock. Reports should present both the field data (apparent) and the interpreted model (true), with an explanation.
How Quantum Geoconsultants can help
We present field data, inverted models and clear interpretations in every survey report. See resistivity survey principles, ERT surveys and geophysical surveys.
Frequently asked questions
What is apparent resistivity?
It is the resistivity a uniform ground would need to produce a given measurement. It blends the effects of all the layers the current passes through.
How is true resistivity obtained?
By inversion or curve matching, which finds a model of layers or cells whose calculated response matches the measured apparent resistivities.
What is the geometric factor?
A number that depends on the positions of the electrodes and converts measured voltage and current into apparent resistivity.
📡 Request a geophysical survey quote
The cost of a geophysical survey depends mainly on the area or length of survey lines, the methods and depth of investigation needed, and site access. Tell us about your project and we will propose a survey design and quotation.
We reply with a proposed survey design and quotation. Prices are not listed online because every site and target is different.
Plan your geophysical survey
Tell us your site, target and depth of interest. We will recommend the right methods and send a survey design and quotation.