The pump’s position in the borehole has a big effect on its performance and life. This article explains how static water level, dynamic water level and pump submergence determine the right setting depth.
Key terms
- Static water level: the water level when the pump has been off for some time.
- Dynamic water level: the level while pumping, lower than the static level.
- Drawdown: the difference between the two.
- Submergence: the depth of water above the pump intake during pumping.
See water levels and drawdown for the hydrogeological background.
Why submergence matters
- Too little submergence lets air or vortices enter the pump, reducing output and causing damage.
- If the water level falls below the intake, the pump runs dry and overheats.
- Pump manufacturers specify minimum submergence for each model.
Setting depth: the rules of thumb
- Start from the dynamic water level at the design pumping rate, from test pumping.
- Add allowance for seasonal decline and long-term changes.
- Add the manufacturer’s minimum submergence.
- Keep the pump above the screens where possible, so water flows past the motor.
- Keep it clear of the bottom of the borehole and the sump, where sediment collects.
Motor cooling
Submersible motors rely on water flowing past them. When the pump is above the screens, incoming water flows upward past the motor. If the pump must be set below the screens, or in a much wider casing, a cooling shroud forces water past the motor.
Seasonal and long-term changes
Water levels in East Africa rise in the rains and fall in dry seasons. In areas with many boreholes, such as parts of Nairobi, levels can decline over years. Regular water level monitoring through a dip tube shows whether the pump setting is still safe.
Protecting against dry running
- Level electrodes in the borehole stop the pump when water falls too low.
- Current-sensing dry-run relays detect the drop in motor load.
- Solar controllers often include dry-run protection.
See control panels and protection.
Example
A borehole has a static level of 40 m and a dynamic level of 62 m at the design rate. Allowing 8 m for seasonal decline and 5 m submergence, the pump is set at about 75 m, provided the screens start below that depth. If screens start at 70 m, a shroud or a smaller pumping rate should be considered.
How Quantum Geoconsultants can help
We set pumps using test pumping and monitoring data. See pump installation, installation procedures and TDH and flow rate.
Frequently asked questions
What is pump submergence?
The depth of water above the pump intake while pumping. Enough submergence prevents air entering the pump and keeps it running smoothly.
Should the pump be set at the bottom of the borehole?
Usually not. Setting it too low risks sediment entering the pump and poor motor cooling if it is below the screens.
Why do water levels fall in the dry season?
Less recharge and more pumping by neighbours lower groundwater levels, so pumps need a margin below the dynamic level.
⚙️ Borehole pump size calculator
Enter your borehole's numbers from the test pumping report (or your best estimate) to see the total head, the flow and roughly how big a submersible pump or solar array you need.
Rough planning figures only. Total head = pumping water level + tank height + an allowance for pipe friction. The final pump is chosen from the manufacturer's pump curves, your test pumping yield and your water quality.
Send these numbers on WhatsAppGet a borehole pump installation quote
Send us your test pumping report, borehole depth and where the tank will sit. We will size the right submersible or solar pump and send a quotation for supply, installation and commissioning.