Get a Quote
← All articles

Pumping Tests in Groundwater Investigations: Principles and Procedures

What a borehole pumping test is, why it is needed, the types of test, how they are carried out and how results set the safe yield and pump design.

By Quantum Geoconsultants hydrogeology teamUpdated 19 November 20262 min read
TopsoilLava flowFractured lava flowWater between lava flowsOlder lavas & tuffs Depth set by the survey

💧 Hydrogeology & Boreholes: a technical article by the Quantum Geoconsultants hydrogeology team.

A borehole’s yield cannot be judged from drilling alone. A pumping test (also called aquifer testing or test pumping) measures how the borehole and aquifer respond to pumping. It is the basis for choosing the right pump and setting a safe pumping rate.

What a pumping test tells you

Types of pumping test

Step drawdown test

The borehole is pumped at several increasing rates, each for a fixed period, often about an hour or more. The results show how drawdown increases with rate and how efficient the borehole is. See step drawdown and constant discharge tests.

Constant rate (constant discharge) test

The borehole is pumped at a steady rate, usually for 24 to 72 hours, while water levels are measured at increasing intervals. This test gives aquifer properties and shows whether drawdown stabilises.

Recovery test

After pumping stops, water level recovery is measured. Recovery data are often more reliable than pumping data because they are not affected by pump fluctuations.

Equipment

Procedure

  1. Measure the static water level before pumping.
  2. Install the pump below the expected dynamic level.
  3. Run the step test, keeping each rate constant.
  4. Allow recovery, then start the constant rate test.
  5. Measure water levels frequently at first (every minute) and then at longer intervals.
  6. Measure discharge regularly and keep it steady.
  7. Take water samples near the end of the test for analysis.
  8. Stop pumping and record recovery until levels are close to the original.

Standards such as BS ISO 14686 and BS EN ISO 22282-4 describe good practice. See BS EN ISO 22282.

Analysis

Drawdown and recovery data are analysed using methods such as Theis, Cooper-Jacob and Theis recovery to calculate transmissivity. Step test data are analysed to separate aquifer losses from well losses. See transmissivity, hydraulic conductivity and storativity.

Setting the safe yield

The recommended pumping rate keeps the dynamic water level safely above the pump and the top of the screens, allows for seasonal decline and long-term effects, and avoids drawing in poor-quality water. It is usually lower than the maximum test rate.

Common mistakes

How Quantum Geoconsultants can help

We carry out and analyse pumping tests and use the results to size pumps and solar systems. See borehole drilling, pump installation and water levels and drawdown.

Frequently asked questions

Why is a pumping test needed?

It measures how much water a borehole can sustainably supply and how the water level responds, which is essential for choosing the pump and setting the pumping rate.

How long is a pumping test?

A typical programme includes a step drawdown test of a few hours and a constant rate test of 24 to 72 hours, followed by recovery monitoring.

Is an airlift yield the same as a pumping test?

No. Airlift yields during drilling are only an indication. A proper pumping test with a submersible pump gives reliable data.

💧 Water demand calculator

How much water does your borehole need to deliver each day? Enter your numbers for a quick planning estimate.

0litres per day
0suggested tank (litres)
0pump flow (m³/hour, solar)

Rough planning figures only, using typical daily use per person and per animal, with one day of storage and about 6 hours of good sun. Your test pumping result sets the final pump size.

Get a borehole quote for Kenya

Send us your location. We will advise on the survey, permits, expected depth and the full cost up to a working solar borehole.

💬 WhatsApp