Vertical Electrical Sounding (VES) is the workhorse of borehole siting in East Africa. It is simple, portable and gives a quick picture of how the ground changes with depth beneath a proposed borehole. This article explains the principles behind a VES survey and how it is used.
The basic idea
Electric current is injected into the ground through two outer electrodes (A and B), and the voltage is measured between two inner electrodes (M and N). As the current electrodes are moved further apart, current flows deeper, so the measurement is influenced by deeper layers. Plotting the measurements against electrode spacing shows how resistivity changes with depth.
Apparent resistivity
Each measurement gives an apparent resistivity: the resistivity a uniform ground would need to give that reading. It is calculated as:
ρa = K × ΔV / I
where ΔV is the measured voltage, I the current and K a geometric factor that depends on electrode positions. Apparent resistivity is a blend of all layers the current passes through, not the true resistivity of a single layer. See apparent versus true resistivity.
The Schlumberger array
In the Schlumberger arrangement, the potential electrodes M and N stay close to the centre while A and B are moved outwards in steps, typically from AB/2 of 1 m out to 100, 200 m or more. M and N are moved only occasionally, which makes fieldwork efficient. The Wenner array, with equal spacing, is an alternative.
Sounding curves
Results are plotted on log-log paper as apparent resistivity against AB/2. The curve shape reveals the layer sequence. For three layers, curve types are often named:
- H-type: low resistivity layer between two higher ones, common where a saturated weathered zone lies between dry cover and fresh rock.
- K-type: high resistivity layer in the middle.
- A-type: resistivity increasing with depth.
- Q-type: resistivity decreasing with depth.
The H-type is often a classic groundwater signature in basement terrain.
Interpretation
Modern interpretation uses inversion software to find a layered model (thicknesses and resistivities) that matches the field curve. The hydrogeologist then translates the model into geology using local knowledge, for example: topsoil, clay, weathered gneiss and fresh gneiss. Traditional curve matching with master curves is still used to check results.
Depth of investigation
As a rough rule, the effective depth of investigation is a fraction of the AB/2 spacing, so reaching 100 m depth may need AB/2 of several hundred metres. Site space, power and noise limit how far electrodes can be spread.
Applications in groundwater exploration
- Estimating depth to water-bearing layers and recommended drilling depth.
- Measuring thickness of weathered zones in basement areas.
- Identifying clay layers to be cased off.
- Detecting saline water in coastal and arid sedimentary basins.
- Comparing several candidate points to rank drilling sites.
Limitations
- Assumes horizontal layers, so it can miss narrow vertical fractures, which ERT detects better.
- Equivalence: different combinations of thickness and resistivity can give almost the same curve.
- Suppression: thin layers may not show.
- Noise from power lines, pipes and fences.
For these reasons, VES works best as part of a combined approach, often with profiling or ERT.
Good field practice
Align the spread along geological strike where possible, avoid metal structures, record electrode contact quality and repeat doubtful readings. Field data quality controls the reliability of the final interpretation.
How Quantum Geoconsultants can help
We carry out VES and ERT surveys for borehole siting and include the data and interpretation in our hydrogeological reports. See hydrogeological surveys in Kenya, geophysical surveys and VES field procedure and interpretation.
Frequently asked questions
What is a VES survey?
A Vertical Electrical Sounding measures apparent resistivity at increasing electrode spacings around a fixed point to work out how resistivity changes with depth.
Which array is used for VES?
The Schlumberger array is most common for groundwater work because it is efficient in the field and less affected by near-surface variations.
What are the limitations of VES?
It assumes horizontal layers, so it can miss narrow vertical fractures, and different layer combinations can give similar curves (equivalence).
💧 Water demand calculator
How much water does your borehole need to deliver each day? Enter your numbers for a quick planning estimate.
Rough planning figures only, using typical daily use per person and per animal, with one day of storage and about 6 hours of good sun. Your test pumping result sets the final pump size.
Send these numbers on WhatsAppGet a borehole quote for Kenya
Send us your location. We will advise on the survey, permits, expected depth and the full cost up to a working solar borehole.