Get a Quote
← All articles

Vertical Electrical Sounding (VES): Principles and Applications in Groundwater Exploration

The principles of Vertical Electrical Sounding: the Schlumberger array, apparent resistivity, sounding curves and layered models, and how VES is applied to borehole siting.

By Quantum Geoconsultants hydrogeology teamUpdated 19 November 20263 min read
TopsoilLava flowFractured lava flowWater between lava flowsOlder lavas & tuffs Depth set by the survey

💧 Hydrogeology & Boreholes: a technical article by the Quantum Geoconsultants hydrogeology team.

Vertical Electrical Sounding (VES) is the workhorse of borehole siting in East Africa. It is simple, portable and gives a quick picture of how the ground changes with depth beneath a proposed borehole. This article explains the principles behind a VES survey and how it is used.

The basic idea

Electric current is injected into the ground through two outer electrodes (A and B), and the voltage is measured between two inner electrodes (M and N). As the current electrodes are moved further apart, current flows deeper, so the measurement is influenced by deeper layers. Plotting the measurements against electrode spacing shows how resistivity changes with depth.

Apparent resistivity

Each measurement gives an apparent resistivity: the resistivity a uniform ground would need to give that reading. It is calculated as:

ρa = K × ΔV / I

where ΔV is the measured voltage, I the current and K a geometric factor that depends on electrode positions. Apparent resistivity is a blend of all layers the current passes through, not the true resistivity of a single layer. See apparent versus true resistivity.

The Schlumberger array

In the Schlumberger arrangement, the potential electrodes M and N stay close to the centre while A and B are moved outwards in steps, typically from AB/2 of 1 m out to 100, 200 m or more. M and N are moved only occasionally, which makes fieldwork efficient. The Wenner array, with equal spacing, is an alternative.

Sounding curves

Results are plotted on log-log paper as apparent resistivity against AB/2. The curve shape reveals the layer sequence. For three layers, curve types are often named:

The H-type is often a classic groundwater signature in basement terrain.

Interpretation

Modern interpretation uses inversion software to find a layered model (thicknesses and resistivities) that matches the field curve. The hydrogeologist then translates the model into geology using local knowledge, for example: topsoil, clay, weathered gneiss and fresh gneiss. Traditional curve matching with master curves is still used to check results.

Depth of investigation

As a rough rule, the effective depth of investigation is a fraction of the AB/2 spacing, so reaching 100 m depth may need AB/2 of several hundred metres. Site space, power and noise limit how far electrodes can be spread.

Applications in groundwater exploration

Limitations

For these reasons, VES works best as part of a combined approach, often with profiling or ERT.

Good field practice

Align the spread along geological strike where possible, avoid metal structures, record electrode contact quality and repeat doubtful readings. Field data quality controls the reliability of the final interpretation.

How Quantum Geoconsultants can help

We carry out VES and ERT surveys for borehole siting and include the data and interpretation in our hydrogeological reports. See hydrogeological surveys in Kenya, geophysical surveys and VES field procedure and interpretation.

Frequently asked questions

What is a VES survey?

A Vertical Electrical Sounding measures apparent resistivity at increasing electrode spacings around a fixed point to work out how resistivity changes with depth.

Which array is used for VES?

The Schlumberger array is most common for groundwater work because it is efficient in the field and less affected by near-surface variations.

What are the limitations of VES?

It assumes horizontal layers, so it can miss narrow vertical fractures, and different layer combinations can give similar curves (equivalence).

💧 Water demand calculator

How much water does your borehole need to deliver each day? Enter your numbers for a quick planning estimate.

0litres per day
0suggested tank (litres)
0pump flow (m³/hour, solar)

Rough planning figures only, using typical daily use per person and per animal, with one day of storage and about 6 hours of good sun. Your test pumping result sets the final pump size.

Get a borehole quote for Kenya

Send us your location. We will advise on the survey, permits, expected depth and the full cost up to a working solar borehole.

💬 WhatsApp