A resistivity survey is only as good as the equipment and the care taken with it. The same site can give clean, repeatable data with well-maintained gear, or noisy, misleading curves with a damaged cable and dry electrodes. This guide explains the main pieces of resistivity survey equipment, what each does and how to keep it working in East African field conditions.
The basic system
Every resistivity measurement needs four things: a way to inject current, a way to measure voltage, electrodes in contact with the ground, and cables to connect them.
| Component | Function |
|---|---|
| Transmitter | Sends a controlled current into the ground through the current electrodes (A and B) |
| Receiver | Measures the voltage between the potential electrodes (M and N) |
| Electrodes | Metal stakes that make electrical contact with the ground |
| Cables | Connect electrodes to the instrument; may be single wires or multi-core spreads |
| Power supply | Batteries or a generator, depending on output needed |
In most modern instruments, the transmitter and receiver are combined in one resistivity meter that calculates the resistance (voltage divided by current) automatically.
Types of resistivity meters
Single-channel meters
These take one measurement at a time. They are ideal for vertical electrical sounding (VES) for borehole siting, where the operator moves the electrodes outward after each reading. They are portable, robust and relatively affordable.
Multi-electrode systems
For 2D ERT, dozens of electrodes are laid out along a line and connected to a switching unit. The instrument automatically selects different electrode combinations and records hundreds of readings without moving anything.
Multi-channel systems
Multi-channel receivers measure several potential pairs at once for each current injection, speeding up surveys considerably. They are common on large ERT and IP projects.
Combined resistivity and IP
Many instruments also measure chargeability, allowing induced polarisation surveys with the same layout.
Key specifications
- Output power and voltage: higher output pushes more current into resistive ground and gives better signal at large spacings.
- Current resolution: accurate current control matters for repeatable readings.
- Receiver sensitivity and noise rejection: important near power lines and in low-signal conditions.
- Stacking: repeating and averaging measurements to reduce noise.
- Data storage and export: for processing in inversion software.
- Ruggedness: dust, heat and transport on rough roads are real tests in Kenya and Somalia.
Electrodes
Stainless steel stakes, typically 30 to 50 cm long, are standard. Things to know:
- Contact resistance is the main problem in dry ground. Drive electrodes deeper, use two stakes together, or water them with salty water.
- Clean electrodes regularly to remove rust and clay.
- Non-polarising electrodes (porous pots with copper sulphate) are used for potential measurements in IP and self-potential surveys.
- On rock outcrops, place electrodes in soil-filled cracks or use wet bentonite to improve contact.
Cables and reels
For VES, long single-core cables on reels carry current to the outer electrodes, sometimes hundreds of metres. For ERT, multi-core cables have take-outs at set intervals for each electrode.
- Check insulation for cuts and abrasion. Leaking current through damaged insulation to wet ground gives false readings.
- Keep connectors clean and dry; use protective caps.
- Lay current and potential cables apart where possible to reduce coupling.
- Avoid running cables along metal fences or pipelines.
Power supply
Most meters run on 12 V batteries. Large spacings or very resistive ground may need external high-voltage boosters or generators. Carry spare charged batteries and protect them from heat.
Supporting equipment
- Measuring tapes or pre-marked cables for spacing.
- GPS for coordinates and elevations, or a total station for topography on ERT lines.
- Hammers, spare electrodes, crocodile clips and repair kit.
- Water containers and salt for watering electrodes.
- Field book or tablet, and a laptop with processing software.
- Radios or phones for communicating along long lines.
Field quality checks
- Check contact resistance before each reading or line.
- Look at the standard deviation or repeat error reported by the meter.
- Plot VES curves in the field; a jump or spike usually means a bad reading worth repeating.
- Repeat a few readings at the end of the day to confirm stability.
- Record nearby features: power lines, fences, pipes, tanks.
Our article on apparent and true resistivity explains what the readings represent once collected.
Safety
Resistivity meters can output hundreds of volts. Keep people and animals away from electrodes during measurements, use clear signals before injecting current, and never touch electrodes or bare connectors while the instrument is transmitting.
How Quantum Geoconsultants can help
We run VES, ERT and IP surveys with calibrated, well-maintained equipment and experienced field teams. See our geophysical surveys in Kenya, ERT surveys and surveys in Somalia.
Frequently asked questions
What equipment is needed for a resistivity survey?
A resistivity meter (transmitter and receiver), at least four electrodes, insulated cables or multi-core cable spreads, a power source, measuring tapes or GPS, and hammers. 2D ERT surveys add a switching unit or multi-electrode system.
What electrodes are used in resistivity surveys?
Stainless steel stakes are standard for current and potential electrodes. Non-polarising porous pot electrodes are sometimes used for potential measurements in IP and self-potential work.
Why do resistivity readings become noisy?
Common causes are poor electrode contact in dry ground, damaged cables, too little current, nearby power lines or metal fences, and wet connectors leaking current.
📡 Request a geophysical survey quote
The cost of a geophysical survey depends mainly on the area or length of survey lines, the methods and depth of investigation needed, and site access. Tell us about your project and we will propose a survey design and quotation.
We reply with a proposed survey design and quotation. Prices are not listed online because every site and target is different.
Plan your geophysical survey
Tell us your site, target and depth of interest. We will recommend the right methods and send a survey design and quotation.