In many parts of northern Kenya and Somalia, the most reliable aquifers lie deep, beneath thick dry sediments or volcanic rocks. Traditional vertical electrical sounding (VES) becomes difficult at these depths: very long cables, poor electrode contact in dry ground and large spreads in rough terrain. Transient electromagnetic (TEM) surveys offer an efficient alternative for deep groundwater exploration.
How TEM works
- A square loop of wire is laid out on the ground, often tens to a few hundred metres per side.
- A steady current flows through the loop, creating a magnetic field.
- The current is switched off abruptly.
- The changing magnetic field induces electrical currents in the ground, which spread outward and downward over time.
- A receiver coil measures the decaying secondary magnetic field at many time intervals.
- Early times reflect shallow layers; later times reflect deeper layers.
The decay curve is inverted to give a resistivity-depth model, similar to a VES result.
Advantages
- Greater depth for a given footprint than resistivity sounding.
- No galvanic contact: no electrodes pushed into the ground, so dry or resistive surfaces are not a problem.
- Good sensitivity to conductive layers, such as saline aquifers and clays.
- Compact layout compared with very long VES spreads.
- Efficient for many soundings across a region.
Limitations
- Less sensitive to resistive layers, which can make thin, resistive aquifer layers harder to resolve.
- Near-surface resolution is limited with large loops; small loops or other methods are needed for shallow layers.
- Cultural noise from power lines, fences, pipes and metal structures.
- Equivalence: different layer models can fit the same data.
- Superparamagnetic and IP effects in some soils can distort late-time data.
Typical applications
- Deep aquifer mapping in sedimentary basins.
- Saline interfaces in coastal and arid aquifers. See groundwater salinity in coastal areas.
- Depth to conductive basement or clay layers.
- Regional groundwater studies with many soundings.
- Volcanic terrains where dry lavas make electrode contact difficult.
Combining TEM with other methods
| Method | Role alongside TEM |
|---|---|
| VES | Better resolution of resistive layers and near surface |
| 2D ERT | Lateral detail in the upper tens of metres. See ERT |
| Magnetics | Structures and dykes controlling groundwater |
| Borehole logs | Calibration of resistivity to geology and water quality |
Joint inversion of TEM and VES data at the same sites combines their strengths. See EM surveys for groundwater.
Field layout
- Central loop: receiver at the centre of the transmitter loop; common for groundwater soundings.
- Coincident loop: the same loop transmits and receives.
- Offset loop: receiver outside the loop, used for some applications.
Loop size is chosen for target depth and ground conductivity. Larger loops and higher currents give deeper penetration.
Interpretation
As with all electrical methods, resistivity values must be interpreted with geology:
- Conductive layers may be clay or saline water. See typical resistivity values.
- Moderately resistive layers below conductive cover may be fresh aquifers.
- Very resistive layers may be dry sediments or fresh hard rock.
Measuring EC of water in nearby boreholes helps distinguish fresh, brackish and saline aquifers.
How Quantum Geoconsultants can help
We select and combine geophysical methods, including EM and resistivity, for deep groundwater exploration in Kenya and Somalia. See our geophysical surveys and hydrogeological surveys in Somalia.
Frequently asked questions
What is a TEM survey?
A geophysical method in which a current in a loop of wire on the ground is switched off abruptly, inducing currents in the ground. The decay of these currents is measured to determine resistivity with depth.
How deep can TEM surveys investigate?
Depending on loop size, equipment and ground conductivity, TEM can investigate from tens of metres to several hundred metres, often deeper than practical VES layouts.
When is TEM better than VES?
When deep aquifers are targeted, when space for long electrode spreads is limited, when surface layers are very dry or resistive, and for mapping saline water interfaces.
📡 Request a geophysical survey quote
The cost of a geophysical survey depends mainly on the area or length of survey lines, the methods and depth of investigation needed, and site access. Tell us about your project and we will propose a survey design and quotation.
We reply with a proposed survey design and quotation. Prices are not listed online because every site and target is different.
Plan your geophysical survey
Tell us your site, target and depth of interest. We will recommend the right methods and send a survey design and quotation.