Pump sizing rests on two numbers: flow rate and total dynamic head (TDH). Together they define the duty point the pump must meet. This article explains both, how they interact and how to estimate pump power.
Flow rate
Flow is the volume of water delivered per unit time, usually m³/h or litres per second. It comes from water demand and pumping hours, limited by borehole safe yield. See pumping capacity.
Total dynamic head
TDH is the sum of:
- Static lift: from the dynamic water level to the highest delivery point (tank inlet)
- Friction losses in pipes, valves and fittings at the design flow
- Pressure head required at delivery, if any
See calculating pumping head for a worked example.
System curve
The system curve shows the head needed at different flows. Static lift stays constant, while friction increases roughly with the square of flow. So doubling flow can greatly increase total head in small pipes.
Pump curve
The pump curve shows the head a pump produces at each flow. Head falls as flow rises. Curves also show efficiency and power.
The duty point
Where the pump curve crosses the system curve is the actual operating point. Good selection places this near the pump’s best efficiency point and within the borehole’s safe yield. See selecting a submersible pump.
Estimating power
Hydraulic power is:
P (W) = 9.81 × Q (L/s) × H (m)
For example, 3 m³/h (0.83 L/s) at 80 m: 9.81 × 0.83 × 80 ≈ 650 W of hydraulic power. With combined pump and motor efficiency of around 45 to 55 percent, input power is roughly 1.2 to 1.5 kW. The motor rating should cover this with margin.
Effect of changing conditions
- Falling water levels increase static lift and reduce flow.
- Clogged pipes or partly closed valves increase friction.
- Raising a tank increases head.
Designing with margins and monitoring performance keeps the system efficient. See pump testing and performance.
Solar systems
With solar, available power varies through the day, so pump speed and flow change. Solar pump selection uses daily volume at a given head and sunshine profile rather than a single duty point. See solar pumping systems.
Common mistakes
- Selecting from head alone without checking flow
- Ignoring friction in long or narrow pipes
- Using static rather than dynamic water level
- Oversizing, which pushes the duty point away from efficiency and beyond safe yield
How Quantum Geoconsultants can help
We calculate TDH, select pumps and verify performance after installation. See pump installation and solar installation.
Frequently asked questions
What is total dynamic head?
The total energy, expressed as metres of water, that a pump must provide to move water at a given flow, including lift, friction and pressure.
What is the duty point?
The flow and head at which the pump operates, where the pump curve meets the system curve.
How do I estimate pump power?
Hydraulic power in watts is about 9.81 × flow (litres per second) × head (metres). Divide by pump and motor efficiency for input power.
⚙️ Borehole pump size calculator
Enter your borehole's numbers from the test pumping report (or your best estimate) to see the total head, the flow and roughly how big a submersible pump or solar array you need.
Rough planning figures only. Total head = pumping water level + tank height + an allowance for pipe friction. The final pump is chosen from the manufacturer's pump curves, your test pumping yield and your water quality.
Send these numbers on WhatsAppGet a borehole pump installation quote
Send us your test pumping report, borehole depth and where the tank will sit. We will size the right submersible or solar pump and send a quotation for supply, installation and commissioning.