When shallow foundations cannot do the job, engineers turn to piles: long columns that carry loads deep into the ground. Piles support tall buildings, bridges, water towers, port structures and buildings on poor ground across Kenya and Somalia. There are many types, each suited to particular ground and project conditions. This article outlines the main options.
How piles carry load
- Shaft friction (skin friction): resistance along the sides of the pile.
- End bearing: resistance at the pile toe, especially in dense sand, gravel or rock.
Friction piles rely mostly on shaft resistance in soils; end-bearing piles transfer load to a strong layer. Most piles use a combination.
Main pile types
Bored cast-in-place piles
A hole is drilled, sometimes supported by temporary casing or drilling fluid, then reinforcement is placed and concrete is poured.
- Diameters from about 300 mm to over 2 m.
- Advantages: low noise and vibration, large capacities, can be socketed into rock, ground conditions seen during boring.
- Limitations: base cleaning and concrete quality are critical; unstable soils and groundwater need casing or support fluid.
Continuous flight auger (CFA) piles
A hollow-stem auger is drilled to depth. Concrete is pumped through the stem as the auger is withdrawn, and reinforcement is pushed into the wet concrete.
- Advantages: fast, quiet, no casing needed in many soils, suited to urban sites.
- Limitations: limited ability to penetrate strong rock or boulders; reinforcement length limited; quality depends on rig instrumentation.
Driven precast concrete piles
Factory-made reinforced or prestressed concrete piles are hammered into the ground.
- Advantages: good quality control, no spoil, capacity can be checked during driving.
- Limitations: noise and vibration, lengths must be planned, can break on boulders or hard layers.
Driven steel piles
Steel H-sections or tubes are driven into the ground. Common in marine and port works.
- Advantages: high capacity, easily spliced, handle hard driving, suitable for over-water work.
- Limitations: corrosion protection needed, especially in seawater; cost.
Driven cast-in-place piles
A steel tube with a closed end is driven, reinforcement is placed and concrete is poured as the tube is withdrawn or left in place.
Micropiles and mini piles
Small diameter (typically under 300 mm) drilled and grouted piles, often with steel bar or tube reinforcement.
- Uses: underpinning, restricted access, retrofit and low headroom.
Short bored piles
Short, small-diameter bored piles are used for light buildings on expansive clays, carrying loads below the active zone. See foundation options for black cotton soil.
Comparison
| Type | Noise and vibration | Spoil | Rock socket | Typical use |
|---|---|---|---|---|
| Bored | Low | Yes | Yes | Buildings, bridges, heavy loads |
| CFA | Low | Yes | Limited | Urban buildings in soils |
| Driven precast | High | No | No | Soft ground, industrial sites |
| Driven steel | High | No | Limited | Ports, jetties, marine |
| Micropiles | Low to moderate | Small | Yes | Underpinning, restricted access |
Ground investigation for piles
- Boreholes deep enough to go several metres below expected pile toe level. See borehole depth.
- SPT or CPT profiles for shaft and base resistance.
- Undisturbed samples of clays for strength.
- Rock coring with strength tests for rock sockets.
- Groundwater levels and chemistry for pile durability.
- Identification of boulders, cavities and obstructions that affect pile installation.
Special considerations
- Negative skin friction where soft soils settle around piles under new fill.
- Uplift in expansive clays and under tension loads.
- Lateral loads from wind, berthing and earth pressure.
- Calcareous sands and coral, which reduce driven pile capacity. See quay wall foundations.
- Pile groups, which behave differently from single piles.
Pile capacity should be confirmed by testing. See static and dynamic pile load testing.
How Quantum Geoconsultants can help
We carry out the deep investigations piles need and provide pile design parameters. See our geotechnical surveys in Kenya, Somalia and our guide to high-rise investigations.
Frequently asked questions
When are pile foundations needed?
When shallow foundations would not carry the loads safely or would settle too much, for example on soft clay, loose fill, expansive soils, or where loads are very high, as in tall buildings, bridges and port structures.
What is the difference between bored and driven piles?
Bored piles are formed by drilling a hole and filling it with reinforced concrete. Driven piles are prefabricated in concrete or steel and hammered into the ground. Driven piles displace soil; bored piles remove it.
What is a CFA pile?
A continuous flight auger pile, made by drilling with a hollow auger and pumping concrete through it as the auger is withdrawn, then inserting reinforcement. It is fast and quiet, and suits many soils.
🏗️ Request a geotechnical survey quote
The scope and cost of a geotechnical investigation depend on the size and type of structure, the site area and the ground conditions. Tell us about your project and we will propose an investigation programme and quotation.
Under the National Building Code 2024, soil testing is now expected before construction. We reply with a proposed programme and quotation.
Book a geotechnical survey in Kenya
Know your ground before you build. Send us your site location and project details and we will propose an investigation programme and quotation.