Rock strength matters for foundations on rock, pile sockets, tunnels, excavation methods, dredging, quarry aggregates and slope stability. The standard laboratory measure is the uniaxial compressive strength (UCS), but UCS tests are slow and need carefully prepared specimens. The point load test is a fast, portable alternative that gives many strength values along a borehole. This article explains how it works and how to use it.
The equipment
A point load tester is a small hydraulic frame with two hardened conical platens. A hand pump applies load and a gauge records the peak load at failure. It can be carried to site and used next to the core boxes.
Types of test
| Test | Specimen | Loading |
|---|---|---|
| Diametral | Core with length at least about 1 times diameter | Across the diameter |
| Axial | Core length about 0.3 to 1 times diameter | Along the core axis |
| Block | Cut block | Between flat faces |
| Irregular lump | Rock lumps of suitable size and shape | Between the most suitable points |
Procedures follow ISRM suggested methods and ASTM D5731.
Calculating the index
- Measure the specimen dimensions and the distance between platen contact points.
- Record the failure load P.
- Calculate the equivalent core diameter De from the specimen geometry.
- Uncorrected point load index Is = P ÷ De².
- Apply a size correction factor to give the standard Is(50), the value for a 50 mm diameter specimen.
Only tests where the fracture passes through both loading points are valid. Tests that chip or fail locally are rejected.
Estimating UCS
Is(50) is often converted to an estimate of UCS:
UCS ≈ K × Is(50)
K is commonly between about 15 and 25 for many rocks, with 20 to 24 often quoted, but it varies with rock type, grain size, porosity and weathering. Weak and porous rocks often give lower factors. The best practice is to calibrate K for the site by running UCS tests on companion specimens.
Anisotropy
Many rocks are stronger in one direction than another: foliated gneisses and schists, bedded sandstones and layered volcanic rocks. Testing parallel and perpendicular to the planes of weakness gives a strength anisotropy index, which matters for slope stability, tunnelling and foundation design in such rocks.
Strength classes
| Is(50) (MPa, approx.) | Indicative strength description |
|---|---|
| Below 0.1 | Very weak to extremely weak |
| 0.1 to 1 | Weak to moderately weak |
| 1 to 3 | Moderately strong to strong |
| 3 to 10 | Strong to very strong |
| Above 10 | Extremely strong |
These bands are approximate; strength descriptions in logs follow BS 5930 and ISO 14689 terms.
Using point load tests in core logging
- Test at regular intervals down each borehole, for example every metre or every lithological change.
- Test fresh core soon after drilling, before it dries or deteriorates, especially for weak rocks.
- Record moisture condition (as received, dry or saturated).
- Plot Is(50) against depth together with TCR, SCR and RQD to build a rock mass profile.
Applications
- Bearing capacity and settlement of foundations on rock.
- Rock socket design for bored piles. See pile types.
- Excavatability and rippability assessment.
- Dredgeability of rock in ports. See dredging projects.
- Quarry rock quality screening. See quarry investigation.
- Rock mass classification systems such as RMR and GSI.
Limitations
- Less reliable in very weak rocks, where platens penetrate rather than split the rock.
- Results scatter more than UCS; enough tests are needed for a meaningful average.
- UCS conversion factors are uncertain without calibration.
- Tests on dried core can overestimate strength of weak, clay-rich rocks.
How Quantum Geoconsultants can help
We carry out point load testing on site during core logging and arrange calibration UCS tests. See our geotechnical surveys in Kenya and Somalia.
Frequently asked questions
What is the point load index?
A measure of rock strength obtained by loading a piece of rock between two conical platens until it breaks. The result is corrected to a standard 50 mm size and reported as Is(50).
How does point load relate to UCS?
Is(50) is commonly multiplied by a conversion factor to estimate unconfined compressive strength. Factors of around 20 to 25 are often quoted, but the factor varies with rock type and should be calibrated with laboratory UCS tests.
Why use the point load test instead of UCS?
It is quick, cheap and portable, can be done on site on core or irregular lumps, and gives many results along a borehole. UCS tests need carefully prepared specimens and a laboratory press.
🏗️ Request a geotechnical survey quote
The scope and cost of a geotechnical investigation depend on the size and type of structure, the site area and the ground conditions. Tell us about your project and we will propose an investigation programme and quotation.
Under the National Building Code 2024, soil testing is now expected before construction. We reply with a proposed programme and quotation.
Book a geotechnical survey in Kenya
Know your ground before you build. Send us your site location and project details and we will propose an investigation programme and quotation.