Black cotton soil: swells & shrinksFirmer weathered layerRock Core box Know your ground before you build

🏗️ Geotechnical Engineering: a technical article by the Quantum Geoconsultants geotechnical team.

Rock strength matters for foundations on rock, pile sockets, tunnels, excavation methods, dredging, quarry aggregates and slope stability. The standard laboratory measure is the uniaxial compressive strength (UCS), but UCS tests are slow and need carefully prepared specimens. The point load test is a fast, portable alternative that gives many strength values along a borehole. This article explains how it works and how to use it.

The equipment

A point load tester is a small hydraulic frame with two hardened conical platens. A hand pump applies load and a gauge records the peak load at failure. It can be carried to site and used next to the core boxes.

Types of test

Test Specimen Loading
Diametral Core with length at least about 1 times diameter Across the diameter
Axial Core length about 0.3 to 1 times diameter Along the core axis
Block Cut block Between flat faces
Irregular lump Rock lumps of suitable size and shape Between the most suitable points

Procedures follow ISRM suggested methods and ASTM D5731.

Calculating the index

  1. Measure the specimen dimensions and the distance between platen contact points.
  2. Record the failure load P.
  3. Calculate the equivalent core diameter De from the specimen geometry.
  4. Uncorrected point load index Is = P ÷ De².
  5. Apply a size correction factor to give the standard Is(50), the value for a 50 mm diameter specimen.

Only tests where the fracture passes through both loading points are valid. Tests that chip or fail locally are rejected.

Estimating UCS

Is(50) is often converted to an estimate of UCS:

UCS ≈ K × Is(50)

K is commonly between about 15 and 25 for many rocks, with 20 to 24 often quoted, but it varies with rock type, grain size, porosity and weathering. Weak and porous rocks often give lower factors. The best practice is to calibrate K for the site by running UCS tests on companion specimens.

Anisotropy

Many rocks are stronger in one direction than another: foliated gneisses and schists, bedded sandstones and layered volcanic rocks. Testing parallel and perpendicular to the planes of weakness gives a strength anisotropy index, which matters for slope stability, tunnelling and foundation design in such rocks.

Strength classes

Is(50) (MPa, approx.) Indicative strength description
Below 0.1 Very weak to extremely weak
0.1 to 1 Weak to moderately weak
1 to 3 Moderately strong to strong
3 to 10 Strong to very strong
Above 10 Extremely strong

These bands are approximate; strength descriptions in logs follow BS 5930 and ISO 14689 terms.

Using point load tests in core logging

Applications

Limitations

How Quantum Geoconsultants can help

We carry out point load testing on site during core logging and arrange calibration UCS tests. See our geotechnical surveys in Kenya and Somalia.

Frequently asked questions

What is the point load index?

A measure of rock strength obtained by loading a piece of rock between two conical platens until it breaks. The result is corrected to a standard 50 mm size and reported as Is(50).

How does point load relate to UCS?

Is(50) is commonly multiplied by a conversion factor to estimate unconfined compressive strength. Factors of around 20 to 25 are often quoted, but the factor varies with rock type and should be calibrated with laboratory UCS tests.

Why use the point load test instead of UCS?

It is quick, cheap and portable, can be done on site on core or irregular lumps, and gives many results along a borehole. UCS tests need carefully prepared specimens and a laboratory press.

🏗️ Request a geotechnical survey quote

The scope and cost of a geotechnical investigation depend on the size and type of structure, the site area and the ground conditions. Tell us about your project and we will propose an investigation programme and quotation.

Under the National Building Code 2024, soil testing is now expected before construction. We reply with a proposed programme and quotation.

Book a geotechnical survey in Kenya

Know your ground before you build. Send us your site location and project details and we will propose an investigation programme and quotation.

💬 WhatsApp