Eurocode 7, published as BS EN 1997, is the European standard for geotechnical design. It is widely used by consultants in Kenya and East Africa, especially on international and donor-funded projects. Its central idea is simple: good design depends on good ground information. This article explains how Eurocode 7 links ground investigation to design.
The two parts
- EN 1997-1: general rules for geotechnical design, including foundations, retaining structures, slopes and piles.
- EN 1997-2: ground investigation and testing, including planning, field and laboratory tests and how to derive geotechnical values.
A second generation of Eurocode 7 has been published and is being introduced over the coming years, with a stronger emphasis on the ground model and reliability. The principles below remain the same.
Geotechnical Categories
Eurocode 7 sorts projects into three categories by complexity and risk:
- Category 1: small, simple structures on known ground with negligible risk.
- Category 2: conventional structures and foundations with no exceptional risk. Most buildings fall here.
- Category 3: large or unusual structures, high risk, or difficult ground, such as high-rise towers on variable ground or major dams.
The category guides how much investigation and expertise are needed.
Limit states
Design checks that the structure does not reach a limit state:
- Ultimate limit states (ULS): failure or collapse. Eurocode 7 names several, including GEO (failure in the ground), STR (structural failure), EQU (loss of equilibrium), UPL (uplift) and HYD (hydraulic failure such as piping).
- Serviceability limit states (SLS): unacceptable settlement, movement or cracking.
From test results to characteristic values
EN 1997-2 describes a chain:
- Measured values from field and laboratory tests.
- Derived values obtained by theory or correlation, for example strength from SPT N-values.
- Characteristic values: a cautious estimate of the value affecting the limit state, chosen by the engineer considering the amount and variability of data and the volume of ground involved.
- Design values: characteristic values with partial factors applied.
The quality of the characteristic value depends directly on the quality of the investigation. Sparse or poor data forces more cautious values and more expensive foundations.
Partial factors and design approaches
Instead of a single factor of safety, Eurocode 7 applies partial factors to actions (loads), material properties and resistances. Three Design Approaches are offered, and national annexes choose which to use. In the UK, Design Approach 1 is used, with two combinations of factors checked. Projects in East Africa usually follow the approach in the specification.
Planning the investigation
EN 1997-2 gives guidance on the spacing and depth of investigation points. For example, it suggests 15 to 40 m spacing for high-rise and industrial structures, and for spread foundations, depths of at least about three times the footing width and not less than about 6 m below foundation level. See investigation for high-rise buildings.
Reports
- Ground Investigation Report (GIR): presents the factual data and its evaluation, including derived values.
- Geotechnical Design Report (GDR): sets out the design assumptions, calculations, characteristic values and requirements for supervision, monitoring and maintenance.
The observational method
Where ground behaviour is hard to predict, Eurocode 7 allows the observational method: the design is reviewed during construction using monitoring, with planned contingency measures if limits are exceeded. It is useful for deep excavations and embankments on soft ground.
How it fits with BS 5930
BS 5930 provides practical guidance on how to carry out investigations, while Eurocode 7 sets out what information design needs and how to use it. Together with BS EN ISO standards for sampling, testing and description, they form a complete framework.
How Quantum Geoconsultants can help
Our investigations are planned to EN 1997-2 and BS 5930, and our reports present derived and characteristic values that designers can use directly. See our geotechnical surveys in Kenya, Somalia and our introduction to geotechnical site investigation.
Frequently asked questions
What is Eurocode 7?
Eurocode 7 (BS EN 1997) is the European standard for geotechnical design. Part 1 covers general rules and Part 2 covers ground investigation and testing.
What is a characteristic value in Eurocode 7?
It is a cautious estimate of the value of a ground parameter that governs the behaviour of the structure, selected by the engineer from test results and experience.
Is Eurocode 7 used in Kenya?
Many consultants in Kenya and East Africa use Eurocode 7 alongside British Standards, and it is often specified for donor-funded and international projects.
🏗️ Request a geotechnical survey quote
The scope and cost of a geotechnical investigation depend on the size and type of structure, the site area and the ground conditions. Tell us about your project and we will propose an investigation programme and quotation.
Under the National Building Code 2024, soil testing is now expected before construction. We reply with a proposed programme and quotation.
Book a geotechnical survey in Kenya
Know your ground before you build. Send us your site location and project details and we will propose an investigation programme and quotation.