When a borehole reaches rock, rotary core drilling recovers a continuous cylinder of rock that tells the engineer a great deal about the ground. Rock core logging turns that core into numbers and descriptions that drive foundation, excavation and tunnel design. Three of the most important measurements are TCR, SCR and RQD.
How rock core is obtained
Rotary coring uses a diamond or tungsten carbide bit on a core barrel, often a double- or triple-tube barrel that protects the core. The core is recovered in runs, typically up to 1.5 or 3 m long, placed in labelled core boxes in the correct order and photographed. Good drilling practice is essential, because poor technique breaks the core and gives misleadingly low quality values.
Total Core Recovery (TCR)
TCR is the total length of core recovered in a run, including broken pieces and fragments, divided by the length of the run, expressed as a percentage.
TCR = (length of core recovered ÷ length of run) × 100
Low TCR can mean weak or broken rock, cavities, soft infilled zones or poor drilling. Where core is lost, the logger records the depth and the likely reason.
Solid Core Recovery (SCR)
SCR counts only the core recovered as solid, full-diameter cylinders, regardless of length. A piece counts if it has a full circumference, even if short.
SCR = (length of full-diameter core ÷ length of run) × 100
SCR shows how much of the rock is intact enough to form solid pieces.
Rock Quality Designation (RQD)
RQD, introduced by Deere, is the sum of the lengths of intact core pieces that are 100 mm or longer, divided by the length of the run.
RQD = (sum of intact pieces ≥ 100 mm ÷ length of run) × 100
Only natural fractures are counted when deciding piece lengths. Breaks caused by drilling or handling are ignored. RQD is widely used in rock mass classification systems such as RMR and Q.
| RQD (%) | Rock quality |
|---|---|
| 0 to 25 | Very poor |
| 25 to 50 | Poor |
| 50 to 75 | Fair |
| 75 to 90 | Good |
| 90 to 100 | Excellent |
A worked example
A 1.5 m core run recovers 1.38 m of material. Of this, 1.20 m is full-diameter core, and the intact pieces 100 mm or longer add up to 0.96 m.
- TCR = 1.38 ÷ 1.5 = 92%
- SCR = 1.20 ÷ 1.5 = 80%
- RQD = 0.96 ÷ 1.5 = 64% (fair rock quality)
Fracture spacing and fracture index
Loggers also record the fracture index (number of natural fractures per metre) or minimum, typical and maximum fracture spacing, together with the dip, roughness, aperture and infill of discontinuities. These details matter for slope stability, excavation and the stiffness of rock foundations.
Describing the rock
Following BS 5930 and BS EN ISO 14689, each rock unit is described in a standard order, including:
- Strength, from extremely weak to extremely strong, often supported by point load tests.
- Weathering, from fresh to completely weathered or residual soil.
- Structure and discontinuities: bedding, joints and faults.
- Colour, grain size and texture.
- Rock name, for example BASALT, TRACHYTE, LIMESTONE or GNEISS.
How the results are used
- Foundations: confirming rockhead level and the quality of rock below pile toes or footings.
- Excavations: assessing rippability and the need for blasting or breaking.
- Slopes and cuttings: judging stability from discontinuities.
- Cavities: low recovery zones in limestone may indicate voids, as found along the Kenyan coast and in parts of Somalia.
Core results can be extended between boreholes using seismic refraction surveys, which map rock depth and quality across a site. In mineral exploration the same measurements are used for different purposes; see core recovery and RQD in exploration drilling.
How Quantum Geoconsultants can help
Our rotary drilling and logging teams recover, photograph and log core to BS 5930 and BS EN ISO 14689, with TCR, SCR, RQD and fracture data on every log. See our geotechnical surveys and BS 5930 guide.
Frequently asked questions
How is RQD calculated?
RQD is the total length of intact core pieces 100 mm or longer, divided by the length of the core run, expressed as a percentage.
What is the difference between TCR and SCR?
TCR counts all core recovered, including fragments. SCR counts only core recovered as full-diameter solid cylinders.
What is a good RQD?
RQD above 90% is described as excellent and 75 to 90% as good, while below 25% is very poor rock quality.
🏗️ Request a geotechnical survey quote