“What is the bearing capacity of my site?” is one of the most common questions an engineer is asked. The answer is never a single number taken from a table. It comes from a geotechnical investigation and careful interpretation of how the ground will behave under a particular foundation. This article explains how soil bearing capacity is determined.
Bearing capacity and settlement: two separate checks
A foundation must satisfy two requirements:
- Bearing resistance (strength): the soil must not fail in shear under the load. The pressure at failure is the ultimate bearing capacity.
- Settlement (serviceability): the foundation must not settle, or settle differentially, so much that the building cracks or tilts.
The allowable bearing pressure is the lower of the pressure that gives an adequate margin against shear failure and the pressure that keeps settlement within limits. On many sites, especially sands and stiff clays, settlement governs.
Step 1: Build the ground model
From borehole and trial pit logs, the engineer identifies each soil and rock layer, its thickness and its variation across the site. Groundwater level is critical, because water reduces effective stress and therefore bearing capacity. A weak layer at depth can control a design even when the surface soil looks strong.
Step 2: Choose design parameters
For each layer, the engineer selects parameters from field and laboratory tests:
- Undrained shear strength (cu) for clays, from triaxial tests, hand vanes or correlations with SPT N-values.
- Angle of shearing resistance (φ’) for sands and gravels, from SPT correlations or shear box tests.
- Unit weight of each soil.
- Stiffness and compressibility (oedometer results, SPT or MASW correlations) for settlement.
- Swell potential for expansive clays.
Under Eurocode 7 these are chosen as characteristic values, a cautious estimate of the value that governs behaviour. See Eurocode 7 explained.
Step 3: Calculate ultimate bearing capacity
The classic bearing capacity equation, developed by Terzaghi and extended by Meyerhof, Hansen and Vesić, combines three contributions:
- Cohesion of the soil (c or cu) multiplied by a factor Nc
- The overburden pressure at foundation level multiplied by Nq
- The self-weight of soil below the footing, which depends on footing width, multiplied by Nγ
The bearing capacity factors depend on φ’, and further factors allow for footing shape, depth, load inclination and groundwater. For a clay under short-term loading, the calculation simplifies to about 5 to 6 times cu for a typical footing.
Step 4: Apply safety
In traditional practice, the ultimate capacity is divided by a factor of safety, often around 3, to get a safe bearing pressure. Under Eurocode 7, partial factors are applied to loads and soil strength instead. Either way, the aim is a reliable margin against failure.
Step 5: Check settlement
Settlement is estimated from soil stiffness:
- Sands: empirical methods based on SPT N-values or stiffness from in-situ tests.
- Clays: immediate settlement plus consolidation settlement from oedometer tests, which can continue for months or years.
- Expansive clays: heave and shrinkage with moisture changes, which are not covered by normal settlement calculations and need special foundation solutions.
Typical limits are around 25 mm total settlement for isolated footings, with smaller limits on differential movement, but the right limit depends on the structure.
Field checks: the plate load test
A plate load test applies load to a steel plate in steps while measuring settlement. It gives a direct check of near-surface behaviour and is useful for slabs, pavements and shallow footings. Because the plate is small, it only tests a shallow zone, so it does not replace boreholes for wider or heavily loaded foundations.
Why presumed bearing values are risky
Tables of presumed bearing values (for example “stiff clay: 150 kPa”) can mislead. They ignore groundwater, weak layers at depth, footing size and settlement limits. On ground such as black cotton soil, coral limestone with cavities or loose fill, using a presumed value can lead to cracking or failure. A proper geotechnical site investigation is the reliable route.
Choosing the foundation
Once bearing capacity and settlement are known, the engineer chooses between strip or pad footings, rafts and piles. Weak or variable ground may lead to deeper foundations or ground improvement, while strong ground allows economical shallow footings.
How Quantum Geoconsultants can help
We provide bearing capacity and settlement assessments as part of our interpretive geotechnical reports. See our geotechnical surveys in Kenya, our Nairobi soil testing service and geotechnical surveys in Somalia.
Frequently asked questions
What is the difference between ultimate and allowable bearing capacity?
Ultimate bearing capacity is the pressure at which the soil fails in shear. Allowable bearing capacity applies a factor of safety and also limits settlement to an acceptable amount.
Can I use a standard bearing capacity value for my site?
Presumed values from tables are only suitable for very small, simple structures on known ground. Most buildings need site-specific values from a ground investigation.
What is a plate load test?
It is a field test where a steel plate is loaded in steps and its settlement measured, giving a direct check of bearing behaviour near the surface.
🏗️ Request a geotechnical survey quote
The scope and cost of a geotechnical investigation depend on the size and type of structure, the site area and the ground conditions. Tell us about your project and we will propose an investigation programme and quotation.
Under the National Building Code 2024, soil testing is now expected before construction. We reply with a proposed programme and quotation.
Book a geotechnical survey in Kenya
Know your ground before you build. Send us your site location and project details and we will propose an investigation programme and quotation.