The Standard Penetration Test (SPT) is the most widely used in-situ test in geotechnical investigations in Kenya and around the world. It is simple, robust and cheap, and the SPT N-value it produces appears in almost every borehole log. This article explains how the test works, what the numbers mean and how they are used in foundation design.
How the SPT is carried out
The test is standardised in BS EN ISO 22476-3. At chosen depths in a borehole, usually every 1 to 1.5 m:
- A split-barrel sampler (or a solid cone in gravel) is lowered to the bottom of a clean borehole.
- A 63.5 kg hammer falls freely through 760 mm onto the drive rods.
- The sampler is first driven 150 mm as a seating drive, which is recorded but not counted.
- It is then driven a further 300 mm. The number of blows for this 300 mm is the N-value.
If 50 blows are reached before the full penetration, the test is usually stopped and recorded as, for example, “50 for 120 mm”. This is often called refusal and indicates very dense soil or rock.
What N-values tell you
In coarse soils (sands and gravels), N-values indicate relative density. A commonly used guide is:
| SPT N-value | Relative density |
|---|---|
| 0 to 4 | Very loose |
| 4 to 10 | Loose |
| 10 to 30 | Medium dense |
| 30 to 50 | Dense |
| Over 50 | Very dense |
In fine soils (clays and silts), N-values give an indication of consistency and undrained shear strength. Correlations such as Stroud’s relate undrained shear strength to N, typically by a factor of about 4 to 6 kPa per blow depending on plasticity. These correlations are useful for preliminary design but should be checked against laboratory strength tests.
Corrections to N-values
Raw field N-values are affected by equipment and depth, so engineers often correct them before use:
- Energy correction (N60): different hammers transfer different energy to the rods. Results are normalised to 60% of the theoretical free-fall energy. Hammer energy calibration should be reported.
- Overburden correction (N1(60)): at greater depth, the same sand gives higher N because of confining stress. Normalising to a standard stress allows layers at different depths to be compared.
- Other factors: rod length, borehole diameter and sampler type, and in fine silty sands below the water table, the possibility of artificially high or low values.
Using N-values in foundation design
Shallow foundations on sand
For pad and strip footings on granular soils, settlement usually governs rather than bearing failure. Classic methods by Terzaghi and Peck, Meyerhof and later Burland and Burbidge use N-values to estimate the pressure that will give an acceptable settlement, often 25 mm. These methods are well established, but they are empirical and should be applied by an experienced engineer with the full ground profile in view.
Clays
In clays, N-values help identify soft layers and give a first estimate of undrained strength for bearing capacity. Settlement of clays, especially soft or swelling clays such as Kenya’s black cotton soils, needs laboratory consolidation and swell tests. Read about bearing capacity from site investigation results.
Piles
N-values are used in empirical pile design methods to estimate shaft friction and end bearing, and to choose the founding level for piles.
Liquefaction and seismic assessment
In loose saturated sands, N1(60) values are used to assess liquefaction potential during earthquakes, relevant in seismically active areas such as parts of the Rift Valley and near the Gulf of Aden.
Limitations of the SPT
- Results depend on equipment, technique and borehole cleanliness.
- Gravel and cobbles can give misleadingly high values.
- In soft clays the test is not sensitive enough; vane or laboratory tests are better.
- Correlations are empirical and site conditions may differ from those used to derive them.
For these reasons, SPT results are best used together with laboratory testing, other in-situ tests and, where helpful, MASW surveys that measure ground stiffness directly.
How Quantum Geoconsultants can help
Our drilling crews carry out SPTs to BS EN ISO 22476-3, record full details on logs and interpret the results with laboratory data in our design recommendations. See our geotechnical surveys in Kenya, geotechnical surveys in Somalia and our guide to BS 5930.
Frequently asked questions
What is an SPT N-value?
It is the number of blows of a 63.5 kg hammer falling 760 mm needed to drive the sampler 300 mm into the soil, after a 150 mm seating drive.
What N-value is good for foundations?
There is no single number. In sands, N above about 30 indicates dense ground, while N below about 10 indicates loose ground that may settle. The right foundation depends on loads, settlement limits and the full ground profile.
Why are SPT N-values corrected?
Hammers deliver different amounts of energy and overburden pressure affects results, so N is often corrected to N60 and N1(60) before being used in correlations.
🏗️ Request a geotechnical survey quote
The scope and cost of a geotechnical investigation depend on the size and type of structure, the site area and the ground conditions. Tell us about your project and we will propose an investigation programme and quotation.
Under the National Building Code 2024, soil testing is now expected before construction. We reply with a proposed programme and quotation.
Book a geotechnical survey in Kenya