Sometimes the most convincing way to know how the ground will behave is to load it and watch. The plate load test does exactly that. A steel plate is placed on the ground and loaded in steps while settlement is measured. It is widely used to check bearing capacity, measure stiffness for pavements and slabs, and verify compaction of fills. This article explains how it works and how to use the results wisely.
Equipment
- Rigid steel plate, typically 300 to 760 mm in diameter.
- Hydraulic jack with a calibrated pressure gauge or load cell.
- Reaction load: a loaded truck, excavator, kentledge (heavy blocks) or anchored beam.
- Dial gauges or displacement transducers, usually three, mounted on a reference beam supported well away from the plate.
Procedure
- Prepare a level test surface at the required depth, removing loose material. Place a thin layer of fine sand or plaster if needed for even contact.
- Seat the plate and apply a small seating load, then zero the gauges.
- Apply load in equal increments.
- Hold each increment until settlement rate falls below a set limit, recording settlement against time.
- Continue to the target load, failure or maximum settlement.
- Unload in steps, recording rebound.
- For pavement and subgrade tests, a second load cycle is often applied.
Procedures and criteria are given in standards such as BS 1377-9 and DIN 18134.
Reading the load-settlement curve
Results are plotted as applied pressure against settlement. The curve shows:
- Initial stiffness: the slope of the early part of the curve.
- Yield or failure: where settlement increases rapidly for small load increases.
- Rebound on unloading, showing elastic versus permanent settlement.
How results are used
Bearing capacity
Where the plate reaches failure, the ultimate bearing pressure under the plate can be read from the curve. Applying it to real foundations needs care, because foundations are larger and stress deeper ground.
Settlement
Plate settlement can be scaled to estimate foundation settlement using empirical relationships, which differ for sands and clays. This is approximate.
Deformation modulus
From the slope of the curve, a deformation modulus (for example Ev1 and Ev2 from first and second load cycles) is calculated. The ratio Ev2/Ev1 is often used as a compaction quality indicator for fills and granular layers.
Modulus of subgrade reaction
For slabs and pavements, the modulus of subgrade reaction (k) is the pressure divided by settlement at a set deflection, used in slab design for warehouses and industrial floors.
Uses
- Checking bearing and stiffness of founding layers for footings.
- Design of industrial floor slabs and hardstandings.
- Quality control of compacted fills and platforms, alongside field density tests.
- Verifying ground improvement.
- Crane pads and temporary works platforms.
Limitations
| Limitation | Consequence |
|---|---|
| Limited depth of influence | Only ground within about one to two plate diameters is tested; deeper soft layers are missed |
| Short duration | Long-term consolidation settlement of clays is not captured |
| Scale effects | Results do not scale simply to large foundations |
| Moisture | Results reflect moisture on the test day; clays may weaken when wet |
| Reaction load needed | Can be costly and time-consuming to arrange |
Because of the depth limitation, plate tests should always be read alongside borehole or trial pit information. A strong crust over soft clay can pass a plate test yet cause large settlement under a building. See borehole depth.
Good practice
- Use a plate size appropriate to the soil particle size and foundation.
- Keep reference beam supports well clear of the loaded zone.
- Protect gauges from sun and wind for stable readings.
- Record ground conditions and moisture at the test location.
- Test at the actual founding level, not the ground surface.
How Quantum Geoconsultants can help
We carry out plate load tests for foundations, floor slabs and fill platforms as part of wider investigations. See our geotechnical surveys in Kenya and guide to bearing capacity.
Frequently asked questions
What is a plate load test?
An in-situ test in which a rigid steel plate is loaded in steps on the ground surface or at the base of a pit, and settlement is measured. It shows how the ground deforms and how much load it can carry.
What size plate is used?
Common diameters range from about 300 mm to 760 mm. Larger plates test a greater depth of ground. The plate should be large compared with the particle size of the soil.
Can a plate load test replace a site investigation?
No. A plate test only reflects the ground within roughly one to two plate diameters below it. Deeper layers that affect real foundations need boreholes and other tests.
🏗️ Request a geotechnical survey quote
The scope and cost of a geotechnical investigation depend on the size and type of structure, the site area and the ground conditions. Tell us about your project and we will propose an investigation programme and quotation.
Under the National Building Code 2024, soil testing is now expected before construction. We reply with a proposed programme and quotation.
Book a geotechnical survey in Kenya
Know your ground before you build. Send us your site location and project details and we will propose an investigation programme and quotation.