How particle size distribution is measured by wet sieving and hydrometer or pipette analysis, how to read a grading curve, D10, D60 and uniformity, and how results are used in design.

By Quantum Geoconsultants geotechnical teamUpdated 20 November 20263 min read
Black cotton soil: swells & shrinksFirmer weathered layerRock Core box Know your ground before you build

🏗️ Geotechnical Engineering: a technical article by the Quantum Geoconsultants geotechnical team.

The particle size distribution (PSD), or grading, is one of the first laboratory tests on almost any soil sample. It tells you how much of the soil is gravel, sand, silt and clay, and it is the basis of soil classification. It also drives practical decisions: whether a soil drains well, how it compacts, what screen slot to use in a water borehole and whether a material meets a road specification.

Size fractions

Under BS EN ISO 14688, the main size fractions are:

Fraction Particle size
Boulders Over 200 mm
Cobbles 63 to 200 mm
Gravel 2 to 63 mm
Sand 0.063 to 2 mm
Silt 0.002 to 0.063 mm
Clay Below 0.002 mm

Gravel, sand and silt are each further divided into coarse, medium and fine. See soil classification under BS EN ISO 14688.

Sieve analysis

Wet sieving

For most natural soils, the sample is first washed through a 63 micron sieve to remove silt and clay that would otherwise stick to the coarser particles. The retained material is dried and passed through a nest of sieves of decreasing aperture, typically from 75 mm down to 63 microns.

Dry sieving

Dry sieving is used only for clean sands and gravels with very little fine material.

Sample size

The sample must be large enough to represent the coarsest particles. A gravelly soil needs several kilograms; a fine sand needs only a few hundred grams. Too small a sample of coarse soil gives an unreliable curve.

Sedimentation: hydrometer and pipette

Sieves cannot separate silt from clay. For the fine fraction, the soil is dispersed in water with a chemical dispersant and allowed to settle. Larger particles settle faster than smaller ones, following Stokes’ law.

The results give the percentage of silt and clay, which matters for plasticity, swelling and permeability. Some tropical and volcanic soils are hard to disperse, which can underestimate the clay fraction; the laboratory should report any problems.

Reading a grading curve

The results are plotted as percentage passing (vertical axis) against particle size on a logarithmic scale (horizontal axis). The shape of the curve tells you a lot:

Key values

Term Meaning
D10 Size at which 10% of the soil is finer; the “effective size”
D30, D60 Sizes at which 30% and 60% are finer
Coefficient of uniformity, Cu D60 ÷ D10. High values mean a wide range of sizes
Coefficient of curvature, Cc (D30)² ÷ (D10 × D60). Used with Cu to judge good grading

How the results are used

Soil classification

Grading, together with Atterberg limits for the fine fraction, determines the soil name and group.

Permeability and drainage

Permeability is strongly related to the fine end of the grading. Empirical formulas such as Hazen’s relate permeability to D10 for clean sands. A small increase in fines can reduce permeability greatly.

Water borehole design

Hydrogeologists use the aquifer grading to choose the screen slot size and gravel pack. A slot that is too large lets sand into the borehole; too small and yield is reduced. See casing and screen installation.

Roads and earthworks

Specifications set grading envelopes for subbase, base and aggregate materials. A natural gravel must fall within the envelope to be accepted. Grading also affects compaction behaviour and the CBR.

Filters and drainage layers

Filter design for dams, drains and retaining walls uses the grading of both the soil and the filter to prevent fine particles being washed out.

Liquefaction and frost

Loose, uniformly graded fine sands and silty sands are the soils most susceptible to liquefaction during earthquakes.

Common mistakes

How Quantum Geoconsultants can help

We test soils and aggregates to BS 1377 and BS EN ISO 17892 for foundations, roads and water boreholes. See our guide to BS 1377 tests and our geotechnical surveys in Kenya.

Frequently asked questions

What is particle size distribution?

It shows the proportions of clay, silt, sand, gravel and coarser particles in a soil, plotted as a grading curve of percentage passing against particle size.

When is a hydrometer test needed?

When a significant part of the soil is finer than 63 microns. Sieves cannot separate silt and clay, so sedimentation methods such as the hydrometer or pipette are used.

What is a well graded soil?

A soil with a wide range of particle sizes in good proportions, so smaller particles fill the gaps between larger ones. It usually compacts well and has good strength.

🏗️ Request a geotechnical survey quote

The scope and cost of a geotechnical investigation depend on the size and type of structure, the site area and the ground conditions. Tell us about your project and we will propose an investigation programme and quotation.

Under the National Building Code 2024, soil testing is now expected before construction. We reply with a proposed programme and quotation.

Book a geotechnical survey in Kenya

Know your ground before you build. Send us your site location and project details and we will propose an investigation programme and quotation.

💬 WhatsApp