Many borehole owners notice the same pattern: the borehole performed well for a few years, then the flow slowly dropped, the tank took longer to fill or the pump started cutting out. Declining borehole yield is common, but it is not always permanent. Finding the cause is the key to restoring it.
Step 1: Is it the pump or the borehole?
Before treating the borehole, check the pumping system:
- Measure the static water level with a dip meter and compare it with the completion report.
- Measure the pumping water level at a known flow rate.
- Measure the actual flow with a meter or by timing how long it takes to fill a container.
| Observation | Likely cause |
|---|---|
| Normal water levels, low flow | Pump wear, leaking rising main, blocked pipes, electrical issues |
| Normal static level, much deeper pumping level than before | Clogging of screens or gravel pack, increased well losses |
| Static level much deeper than before | Regional water level decline, interference from nearby boreholes, drought |
| Sudden drop with sand or mud | Casing or screen damage, collapse |
See static and dynamic water levels and pumping problems.
Common causes of borehole yield decline
Physical clogging
Fine silt and clay migrate towards the borehole and block the gravel pack and screen slots. This happens faster if development was incomplete or if the borehole is over-pumped.
Chemical encrustation
Hard water and changes in pressure and temperature can cause calcium carbonate scale to form on screens. Iron and manganese can precipitate as oxides. See iron and manganese.
Biological fouling
Iron bacteria and other organisms form slime that blocks screens and gravel pack, often together with iron deposits.
Aquifer decline
If more water is pumped from the aquifer than recharge replaces, levels fall over time. Drought, new nearby boreholes and increased pumping all contribute. Cleaning the borehole cannot fix this. See sustainable groundwater development.
Structural problems
Corroded or broken casing, collapsed screens or infill from the formation reduce the open section of the borehole.
Pump problems
Worn impellers, partially blocked intakes, leaking rising main joints and incorrect voltage all reduce flow.
Step 2: Inspect the borehole
A downhole camera inspection shows the condition of casing and screens, the presence of encrustation, slime, damage or infill, and the depth to the bottom compared with the original depth. It is the best way to decide what treatment is needed. See what a camera inspection reveals.
Step 3: Restore yield
Mechanical cleaning
- Brushing screens and casing to remove deposits.
- Bailing or air-lifting to remove infill from the bottom.
- Surging with a surge block to pull fines out of the gravel pack.
- High-pressure jetting through the screen slots.
- Air-lift flushing to remove loosened material. See borehole flushing.
Chemical treatment
- Acid treatment to dissolve carbonate scale and iron deposits, using suitable acids and inhibitors, followed by thorough pumping out.
- Chlorination or other biocides to kill iron bacteria and slime.
- Dispersants to help remove clay fines.
Chemical treatments must be compatible with casing and screen materials, and treated water must be disposed of safely.
Pump repair or replacement
Repair or replace worn pumps, fix leaking joints and resize the pump to the current yield if it has changed.
Step 4: Test after treatment
After rehabilitation, run a step test or constant rate test to measure the new yield and drawdown, and compare with the original. This sets the correct pumping rate going forward. See pumping tests.
Prevention
- Pump within the safe yield.
- Monitor water levels and flow monthly, and keep records.
- Schedule inspections and cleaning before yield drops severely.
- Use corrosion-resistant casing and screens.
- Keep the headworks sealed to prevent contamination.
When to consider a new borehole
If the casing is badly damaged, the aquifer has declined significantly, or rehabilitation costs approach the cost of a new borehole, redrilling may be better. See borehole rehabilitation: repair or redrill.
How Quantum Geoconsultants can help
We diagnose yield problems with water level measurements, camera inspections and pump tests, then clean and rehabilitate boreholes. See our borehole flushing and camera inspection services.
Frequently asked questions
Why has my borehole yield dropped?
Common causes are clogging of screens and the gravel pack by fines, scale or iron bacteria; falling regional water levels; pump wear or a leaking rising main; and collapse or damage inside the borehole.
Can a low-yield borehole be restored?
Often yes, if the cause is clogging or pump problems. Cleaning, flushing, chemical treatment and pump repair can restore much of the original yield. If the aquifer itself is depleted, yield cannot be fully restored by cleaning.
How do I know if it is the pump or the borehole?
Measure water levels and pump output. If the water level is normal but flow is low, the pump or pipes are likely at fault. If the water level drops much further than before at the same flow, the borehole or aquifer is the problem.
💧 Water demand calculator
How much water does your borehole need to deliver each day? Enter your numbers for a quick planning estimate.
Rough planning figures only, using typical daily use per person and per animal, with one day of storage and about 6 hours of good sun. Your test pumping result sets the final pump size.
Send these numbers on WhatsAppGet a borehole quote for Kenya
Send us your location. We will advise on the survey, permits, expected depth and the full cost up to a working solar borehole.