In much of coastal Kenya, northern Kenya and Somalia, boreholes produce water that is too salty to drink comfortably or safely. Where fresher sources are not available, reverse osmosis (RO) can turn brackish borehole water into good drinking water. Small RO systems now serve homes, schools, clinics, hotels and communities. This article explains how they work and what it takes to run them well.
How RO works
Water is pumped at pressure against a semi-permeable membrane. Water molecules pass through; most dissolved salts and many other contaminants do not. The result is two streams:
- Permeate: treated, low-salinity water.
- Concentrate (brine): water with the rejected salts, which must be disposed of.
Brackish water RO needs much lower pressure, and less energy, than seawater desalination.
System components
| Component | Purpose |
|---|---|
| Feed pump | Supplies water from borehole or tank |
| Pre-treatment | Sediment filters, iron removal, antiscalant dosing, carbon filters |
| High-pressure pump | Pushes water through membranes |
| Membrane housings | Hold the RO membranes |
| Post-treatment | Remineralisation and pH adjustment, disinfection |
| Storage | Treated water tank |
| Controls and instruments | Pressure gauges, flow meters, conductivity meters |
Pre-treatment is critical
Membranes are easily damaged or fouled by:
- Suspended solids and sand. See sand in borehole water.
- Iron and manganese, which oxidise and coat membranes. See iron and manganese.
- Hardness and carbonates that form scale.
- Bacteria and biofilm.
- Chlorine, which damages many membrane types.
A full water analysis before design is essential. See water testing in Kenya.
Recovery and brine
Recovery is the percentage of feed water that becomes treated water. Higher recovery saves water but increases scaling risk. For brackish water, small systems often run at moderate recovery. Brine disposal options include:
- Evaporation ponds in arid areas.
- Discharge to sewer where permitted.
- Controlled discharge or reinjection where environmental rules allow.
- Use for salt-tolerant purposes where suitable.
Brine must not be allowed to contaminate soils or other water sources.
Sizing
- Decide which water needs treatment. Often only drinking and cooking water is treated, which greatly reduces system size. See daily water demand.
- Calculate feed water needed: treated water ÷ recovery.
- Check the borehole can supply the feed volume within its safe yield.
- Size storage for treated water to cover peak use and downtime.
Solar-powered RO
In off-grid areas, RO can run on solar power, usually during the day, with treated water stored for evening use. Some systems include batteries for steadier operation. Solar arrays must be sized for both the borehole pump and the RO pumps. See sizing solar arrays and hybrid systems.
Operating costs
- Energy for pumps.
- Pre-filter cartridges, replaced regularly.
- Antiscalant and cleaning chemicals.
- Membrane replacement every few years, depending on care.
- Operator time and water testing.
Maintenance
- Monitor feed and permeate conductivity daily; rising permeate conductivity signals problems.
- Record pressures and flows; rising pressure difference suggests fouling.
- Replace pre-filters on schedule.
- Clean membranes chemically when performance drops.
- Keep treated water storage clean and disinfected. See water quality in storage tanks.
Alternatives and complements
- Rainwater harvesting for drinking water. See rainwater harvesting vs borehole.
- Siting a new borehole in a fresher aquifer. See salty borehole water.
- Blending brackish and fresh water for some uses.
How Quantum Geoconsultants can help
We test borehole water, advise on treatment and design borehole, pumping and storage systems that work with RO. See our pump installation and hydrogeological surveys in Somalia.
Frequently asked questions
Can reverse osmosis make salty borehole water drinkable?
Yes. RO removes most dissolved salts, as well as fluoride, nitrate and many other contaminants, producing water suitable for drinking when the system is properly designed and maintained.
How much water does an RO system waste?
Part of the feed water becomes concentrated brine. For brackish water, small systems commonly recover around 50 to 75 percent as treated water, depending on salinity and design, so the rest must be disposed of.
Can RO run on solar power?
Yes. Solar-powered RO units are used in off-grid areas, often running in daylight and storing treated water in tanks.
⚙️ Borehole pump size calculator
Enter your borehole's numbers from the test pumping report (or your best estimate) to see the total head, the flow and roughly how big a submersible pump or solar array you need.
Rough planning figures only. Total head = pumping water level + tank height + an allowance for pipe friction. The final pump is chosen from the manufacturer's pump curves, your test pumping yield and your water quality.
Send these numbers on WhatsAppGet a borehole pump installation quote
Send us your test pumping report, borehole depth and where the tank will sit. We will size the right submersible or solar pump and send a quotation for supply, installation and commissioning.