A good borehole and pump can be let down by the pipes. Pipes that are too small cause low pressure at the taps, starve distant users and waste energy. Pipes that are too large cost more than necessary. Pipe sizing balances flow, pressure, cost and durability. This article explains the basics for borehole water distribution systems.
Step 1: Design flow
Start with demand. For pipes, what matters is the peak flow, not the daily total.
- Rising main (pump to tank): sized for the pump flow rate.
- Distribution mains (tank to users): sized for peak hourly demand, often 2 to 3 times the average hourly demand.
- Service lines to buildings: sized for the number of fixtures likely to be in use at once.
See calculating daily water demand.
Step 2: Velocity
Velocity = flow ÷ pipe cross-sectional area. A practical range in water supply is about 0.5 to 2 m/s:
- Below about 0.5 m/s, sediment can settle and water may stagnate.
- Above about 2 m/s, friction losses, noise and water hammer increase.
| Pipe internal diameter (approx.) | Flow at 1 m/s |
|---|---|
| 25 mm | About 1.8 m³/h |
| 32 mm | About 2.9 m³/h |
| 50 mm | About 7.1 m³/h |
| 63 mm | About 11 m³/h |
| 90 mm | About 23 m³/h |
| 110 mm | About 34 m³/h |
Note that plastic pipes are usually specified by outside diameter; internal diameter depends on the pressure class and wall thickness.
Step 3: Friction losses
Water loses pressure as it flows through pipes and fittings. Losses depend on:
- Flow rate (losses rise roughly with the square of velocity).
- Pipe diameter (smaller pipes lose much more).
- Pipe length.
- Pipe roughness (smooth plastic loses less than old steel).
- Fittings: bends, valves, tees and meters.
Engineers use the Hazen-Williams or Darcy-Weisbach equations, or manufacturer tables, to calculate head loss per 100 m of pipe. Fittings are often added as an equivalent length or a percentage allowance.
Step 4: Pressure check
At the furthest or highest outlet:
Available pressure = supply head − elevation gain − friction losses
The supply head is the tank water level (for gravity systems) or the pump or booster pressure. Most domestic taps and showers work well with around 10 to 30 m of residual head. Check also that pressure at the lowest points does not exceed the pipe rating. See water pressure and hydraulic head.
Worked example
A school is supplied by gravity from an elevated tank. The tank’s water level is 12 m above the furthest tap block, 400 m away. Peak flow to the block is 4 m³/h.
| Option | Velocity | Approx. friction loss over 400 m* | Residual head |
|---|---|---|---|
| 32 mm HDPE | About 1.8 m/s | Very high, well over 12 m | Insufficient |
| 50 mm HDPE | About 0.7 m/s | Roughly 4 to 6 m | About 6 to 8 m: marginal |
| 63 mm HDPE | About 0.45 m/s | Roughly 1.5 to 2 m | About 10 m: acceptable |
*Indicative figures; actual losses depend on internal diameter, fittings and the pipe class. Use manufacturer tables for design.
Here, 63 mm pipe gives adequate pressure, or the tank could be raised. See hydraulic design of water tower distribution.
Pipe materials
| Material | Advantages | Considerations |
|---|---|---|
| HDPE | Flexible, tough, long coils, few joints, corrosion free | Needs proper fusion or compression fittings; UV protection if exposed |
| uPVC | Affordable, smooth, widely available | Brittle if exposed to sun or impact; needs careful bedding |
| Galvanised steel | Strong, good for exposed sections | Corrodes, especially with aggressive water; rougher over time |
| PPR | Good for hot and cold building plumbing | Mainly for internal plumbing |
Pressure class
Choose a pressure class that safely exceeds the maximum working pressure, including surges from pump starts and valve closures. Water hammer can be several times normal pressure in long mains. Use slow-closing valves and air valves at high points.
Installation tips
- Bury pipes deep enough to protect from traffic and sun.
- Bed and backfill with fine material, free of stones.
- Install air release valves at high points and washouts at low points.
- Fit isolation valves to sections for maintenance.
- Record pipe routes in an as-built drawing. See as-built surveys.
How Quantum Geoconsultants can help
We design and install borehole pumping and distribution systems, including towers, pipework and pressure systems. See our pump installation and water tower construction services.
Frequently asked questions
How do I choose the right pipe size?
Calculate the design flow, choose a pipe that keeps velocity within a sensible range, typically about 0.5 to 2 m/s, then check friction losses so that enough pressure remains at the far end.
What pipe material is best for borehole water?
HDPE and uPVC are widely used for distribution because they resist corrosion, are light and are relatively affordable. Galvanised steel is used in exposed or high-temperature sections but corrodes over time.
What happens if pipes are too small?
Friction losses increase sharply, pressure at taps drops, pumps work harder and energy costs rise. Too-large pipes cost more and can have low velocities that allow sediment to settle.
⚙️ Borehole pump size calculator
Enter your borehole's numbers from the test pumping report (or your best estimate) to see the total head, the flow and roughly how big a submersible pump or solar array you need.
Rough planning figures only. Total head = pumping water level + tank height + an allowance for pipe friction. The final pump is chosen from the manufacturer's pump curves, your test pumping yield and your water quality.
Send these numbers on WhatsAppGet a borehole pump installation quote
Send us your test pumping report, borehole depth and where the tank will sit. We will size the right submersible or solar pump and send a quotation for supply, installation and commissioning.