Concrete foundations, piles, basements and buried pipes sit in contact with soil and groundwater for decades. If that ground contains sulphates, chlorides or acids, the concrete and its reinforcement can deteriorate long before the end of the design life. Simple chemical tests during the site investigation tell the designer how aggressive the ground is. This article explains which sulphate, chloride and pH tests are needed and how they are used.
Where aggressive ground occurs
- Coastal areas with saline groundwater and sea spray.
- Arid areas with gypsum-rich soils and salt crusts. See sabkha soils.
- Marine clays and mudstones that contain pyrite, which can oxidise to sulphate when disturbed.
- Peat and organic soils with acidic groundwater.
- Industrial and waste sites with chemical contamination.
The main tests
| Test | What it measures | Why it matters |
|---|---|---|
| Water-soluble sulphate (2:1 extract) | Sulphate readily available to attack concrete | Main input to sulphate class |
| Sulphate in groundwater | Sulphate in mobile water | Often controls design class |
| Acid-soluble sulphate | Total sulphate, including less soluble forms | Indicates potential sulphate |
| Total sulphur | All sulphur, including pyrite | Identifies risk of pyrite oxidation creating more sulphate |
| pH | Acidity of soil and water | Acid attack on concrete |
| Chloride (soil and water) | Chloride ions | Corrosion risk to reinforcement |
| Magnesium | Magnesium ions | Magnesium sulphate is particularly aggressive |
| Ammonium, nitrate | Other aggressive ions | Relevant at contaminated sites |
Sampling
- Take samples from each soil layer in contact with concrete, especially at foundation depth.
- Take groundwater samples from boreholes or piezometers, not from water that has mixed with drilling fluid. See installing piezometers.
- Seal samples to avoid oxidation and moisture loss. See sample storage.
- Test enough samples to capture variability; aggressive conditions can be patchy.
- Record whether groundwater is static or mobile, as mobility affects severity.
From results to concrete specification
In British and European practice, BRE Special Digest 1 and BS 8500 use test results to assign:
- A design sulphate class (DS class).
- An aggressive chemical environment for concrete class (ACEC class), considering pH and groundwater mobility.
Chloride exposure classes are set from the presence of chlorides in ground, groundwater and seawater. These classes then determine:
- Cement types and combinations.
- Maximum water-cement ratio and minimum strength.
- Minimum cover to reinforcement.
- Additional protective measures, such as membranes or coatings.
The geotechnical report should present results in a summary table and state the recommended classes. See how to read a geotechnical report.
Protecting concrete
- Use the specified cement and mix design.
- Ensure good compaction and curing; poor workmanship undoes good specifications.
- Use adequate cover spacers.
- Apply waterproof membranes or coatings on buried surfaces in severe conditions.
- Use corrosion-resistant reinforcement or inhibitors in critical elements.
See aggressive ground and marine concrete.
Steel and other materials
The same tests help assess corrosion risk to buried steel, such as piles and pipelines. Soil resistivity and redox potential tests may be added for steel. Plastic pipes are generally resistant, but contamination may still matter.
Common mistakes
- Testing only one sample on a large site.
- No groundwater testing.
- Ignoring pyrite in clays and mudstones.
- Not passing the results and classes to the structural designer and contractor.
How Quantum Geoconsultants can help
We include chemical testing of soils and groundwater in our investigations and report design classes for durable concrete. See our geotechnical surveys in Kenya, Mombasa and Somalia.
Frequently asked questions
Why test soil for sulphate?
Sulphates react with cement in concrete and form expansive compounds that crack and weaken it. Knowing sulphate levels allows the engineer to specify a concrete mix that resists attack.
Why test for chloride?
Chlorides penetrate concrete and corrode the steel reinforcement. High chloride levels, common near the coast and in saline soils, require denser concrete and greater cover.
Should I test soil or groundwater?
Both where possible. Groundwater often controls the severity of attack, because mobile water continually supplies aggressive ions to the concrete.
🏗️ Request a geotechnical survey quote
The scope and cost of a geotechnical investigation depend on the size and type of structure, the site area and the ground conditions. Tell us about your project and we will propose an investigation programme and quotation.
Under the National Building Code 2024, soil testing is now expected before construction. We reply with a proposed programme and quotation.
Book a geotechnical survey in Kenya
Know your ground before you build. Send us your site location and project details and we will propose an investigation programme and quotation.