Get a Quote
← All articles

Plate Load Test: Procedure, Results and Design Use

How the plate load test is carried out, what load-settlement curves show, how results are used for bearing capacity, settlement, modulus of subgrade reaction and compaction checks, and its limitations.

By Quantum Geoconsultants geotechnical teamUpdated 20 November 20263 min read
Black cotton soil: swells & shrinksFirmer weathered layerRock Core box Know your ground before you build

🏗️ Geotechnical Engineering: a technical article by the Quantum Geoconsultants geotechnical team.

Sometimes the most convincing way to know how the ground will behave is to load it and watch. The plate load test does exactly that. A steel plate is placed on the ground and loaded in steps while settlement is measured. It is widely used to check bearing capacity, measure stiffness for pavements and slabs, and verify compaction of fills. This article explains how it works and how to use the results wisely.

Equipment

Procedure

  1. Prepare a level test surface at the required depth, removing loose material. Place a thin layer of fine sand or plaster if needed for even contact.
  2. Seat the plate and apply a small seating load, then zero the gauges.
  3. Apply load in equal increments.
  4. Hold each increment until settlement rate falls below a set limit, recording settlement against time.
  5. Continue to the target load, failure or maximum settlement.
  6. Unload in steps, recording rebound.
  7. For pavement and subgrade tests, a second load cycle is often applied.

Procedures and criteria are given in standards such as BS 1377-9 and DIN 18134.

Reading the load-settlement curve

Results are plotted as applied pressure against settlement. The curve shows:

How results are used

Bearing capacity

Where the plate reaches failure, the ultimate bearing pressure under the plate can be read from the curve. Applying it to real foundations needs care, because foundations are larger and stress deeper ground.

Settlement

Plate settlement can be scaled to estimate foundation settlement using empirical relationships, which differ for sands and clays. This is approximate.

Deformation modulus

From the slope of the curve, a deformation modulus (for example Ev1 and Ev2 from first and second load cycles) is calculated. The ratio Ev2/Ev1 is often used as a compaction quality indicator for fills and granular layers.

Modulus of subgrade reaction

For slabs and pavements, the modulus of subgrade reaction (k) is the pressure divided by settlement at a set deflection, used in slab design for warehouses and industrial floors.

Uses

Limitations

Limitation Consequence
Limited depth of influence Only ground within about one to two plate diameters is tested; deeper soft layers are missed
Short duration Long-term consolidation settlement of clays is not captured
Scale effects Results do not scale simply to large foundations
Moisture Results reflect moisture on the test day; clays may weaken when wet
Reaction load needed Can be costly and time-consuming to arrange

Because of the depth limitation, plate tests should always be read alongside borehole or trial pit information. A strong crust over soft clay can pass a plate test yet cause large settlement under a building. See borehole depth.

Good practice

How Quantum Geoconsultants can help

We carry out plate load tests for foundations, floor slabs and fill platforms as part of wider investigations. See our geotechnical surveys in Kenya and guide to bearing capacity.

Frequently asked questions

What is a plate load test?

An in-situ test in which a rigid steel plate is loaded in steps on the ground surface or at the base of a pit, and settlement is measured. It shows how the ground deforms and how much load it can carry.

What size plate is used?

Common diameters range from about 300 mm to 760 mm. Larger plates test a greater depth of ground. The plate should be large compared with the particle size of the soil.

Can a plate load test replace a site investigation?

No. A plate test only reflects the ground within roughly one to two plate diameters below it. Deeper layers that affect real foundations need boreholes and other tests.

🏗️ Request a geotechnical survey quote