Triaxial Testing: UU, CU and CD Tests Explained

How the triaxial test works, the differences between unconsolidated undrained, consolidated undrained and consolidated drained tests, what parameters they give and when each is used in design.

By Quantum Geoconsultants geotechnical teamUpdated 20 November 20263 min read
Black cotton soil: swells & shrinksFirmer weathered layerRock Core box Know your ground before you build

🏗️ Geotechnical Engineering: a technical article by the Quantum Geoconsultants geotechnical team.

The triaxial test is the workhorse of soil strength testing. It is used to design foundations, slopes, embankments, retaining walls and excavations, especially in clays. But triaxial results are only useful if the right type of test is chosen for the design question. This article explains how the test works and the differences between UU, CU and CD tests.

How a triaxial test works

A cylindrical soil specimen, typically 38 mm or 100 mm in diameter and twice as tall, is enclosed in a thin rubber membrane and placed in a cell filled with water. The water is pressurised to apply an all-round confining pressure, simulating the stress in the ground. A loading ram then pushes down on the specimen, increasing the vertical stress until it fails.

The key controls are:

Total and effective stress

Soil strength depends on effective stress, the stress carried by the soil skeleton, which equals total stress minus pore water pressure. When a saturated clay is loaded quickly, water cannot escape and pore pressure rises, so effective stress and strength do not increase immediately. Over time, water drains and the clay gains strength. Triaxial tests reproduce these conditions in different ways.

The three main tests

Unconsolidated undrained (UU)

Consolidated undrained (CU) with pore pressure measurement

Consolidated drained (CD)

Comparison

Test Consolidation Drainage during shear Main results Typical design use
UU No No cu Short-term stability of clays
CU Yes No (pore pressure measured) cu, c′, φ′ Long-term and staged construction
CD Yes Yes c′, φ′ Long-term conditions, sands

Reading the results

Results are usually shown as stress-strain curves and as Mohr circles or stress path plots. A line drawn tangent to the circles from several specimens gives the failure envelope, defined by cohesion and friction angle. The report should also show:

Sample quality matters

Triaxial results are only as good as the samples. Disturbed samples give lower undrained strength and misleading stiffness. Use good quality undisturbed samples from thin-walled tubes or blocks, and handle them carefully. See storing and transporting samples and foundations on soft clay.

Triaxial versus other strength tests

Specifying triaxial tests

  1. Identify the design situations: short-term, long-term or both.
  2. Select test type and confining pressures to match field stresses.
  3. Choose representative samples from each important layer.
  4. Ask for full reporting, not just c and φ values.

How Quantum Geoconsultants can help

We take high-quality samples and arrange triaxial testing to match the design questions on each project. See our geotechnical surveys in Kenya and guide to BS 1377 tests.

Frequently asked questions

What does a triaxial test measure?

The shear strength of a soil sample under controlled confining pressure and drainage conditions. Depending on the test type, it gives undrained shear strength or effective strength parameters (cohesion and friction angle), plus stiffness information.

Which triaxial test should I specify?

UU tests give undrained strength for short-term stability of clays. CU tests with pore pressure measurement give effective strength parameters more quickly than CD tests. CD tests give drained parameters directly but take much longer in clays.

How many triaxial tests are needed?

Usually at least three specimens per test, at different confining pressures, for each soil layer that matters to design. More tests are needed where layers vary or design is sensitive to strength.

🏗️ Request a geotechnical survey quote

The scope and cost of a geotechnical investigation depend on the size and type of structure, the site area and the ground conditions. Tell us about your project and we will propose an investigation programme and quotation.

Under the National Building Code 2024, soil testing is now expected before construction. We reply with a proposed programme and quotation.

Book a geotechnical survey in Kenya

Know your ground before you build. Send us your site location and project details and we will propose an investigation programme and quotation.