Assay results drive exploration decisions and resource estimates worth millions. QA/QC (quality assurance and quality control) proves that those results can be trusted. This article explains the main control samples and how to use them.
Accuracy, precision and contamination
- Accuracy: are results close to the true value? Checked with standards.
- Precision: are results repeatable? Checked with duplicates.
- Contamination: is material carried between samples? Checked with blanks.
Certified reference materials (standards)
Standards are commercially prepared materials with a certified grade and expected variability. They are inserted blind (without the laboratory knowing) at regular intervals. Choose standards with grades similar to the project’s mineralisation: low, medium and high.
Blanks
- Coarse blanks: barren rock inserted before crushing, testing preparation contamination.
- Pulp blanks: barren pulps testing analytical contamination.
Blanks are often inserted after high-grade samples, where contamination risk is greatest.
Duplicates
- Field duplicates: second split of RC samples or quarter core, measuring total sampling variability.
- Coarse reject duplicates: second split after crushing, measuring preparation variability.
- Pulp duplicates: repeat analysis of pulps, measuring analytical precision.
Comparing these separates the sources of error.
Umpire laboratory checks
A portion of pulps, commonly a few percent, is sent to a second accredited laboratory to check for bias at the primary laboratory.
Insertion rates
Programmes commonly insert control samples at a combined rate of around 10 to 20 percent of all samples, split between standards, blanks and duplicates, with higher rates in critical phases. The exact rate should be stated in the QA/QC procedure.
Monitoring
- Control charts plot standard results against expected values, with warning and failure limits commonly set at two and three standard deviations.
- Blank charts flag values above a set multiple of the detection limit.
- Scatter and relative difference plots evaluate duplicates.
Corrective action
When a control sample fails:
- Check for mislabelling or data entry errors.
- Ask the laboratory to re-assay the batch or the samples around the failure.
- Investigate causes: calibration, contamination or preparation issues.
- Document the outcome.
Accepting data without acting on failures undermines the whole programme.
QA/QC and resource reporting
Reporting codes such as JORC and NI 43-101 expect QA/QC to be described and its results discussed. Poor QA/QC can prevent a resource from being classified with confidence. See mineral resource estimation.
How Quantum Geoconsultants can help
We set up QA/QC procedures, monitor results and prepare QA/QC reports. See sampling techniques and mineral exploration.
Frequently asked questions
Why is QA/QC required?
It demonstrates that assay results are accurate and precise, which is required for reliable decisions and for public reporting of mineral resources.
What is a certified reference material?
A sample with a known, certified grade inserted among exploration samples to check laboratory accuracy.
What does a blank detect?
Contamination during sample preparation or analysis, shown when a barren blank returns elevated values.
📡 Request a geophysical survey quote
The cost of a geophysical survey depends mainly on the area or length of survey lines, the methods and depth of investigation needed, and site access. Tell us about your project and we will propose a survey design and quotation.
We reply with a proposed survey design and quotation. Prices are not listed online because every site and target is different.
Plan your geophysical survey
Tell us your site, target and depth of interest. We will recommend the right methods and send a survey design and quotation.